LT100-S-SP30 Datasheet, PDF (1/2 Pages) LEM – Current Transducer | |||
|
Current Transducer LT 100-S/SP30
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 100 A
Electrical data
16240
IPN
Primary nominal r.m.s. current
IP
Primary current, measuring range
RM Measuring resistance
with ± 12 V
with ± 18 V
@ ± 100 A
max
@ ± 200 A max
@ ± 100 A
max
@ ± 200 A max
I
Secondary nominal r.m.s. current
SN
K N Conversion ratio
V
Supply voltage (± 5 %)
C
IC
Current consumption
V
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
d
100
A
0 .. ± 200
A
RM min
RM max
0
75 ï
0
25 ï
30
135 ï
30
55 ï
100
mA
1 : 1000
± 12 .. 18
V
28 (@ ± 18 V) + IS mA
5
kV
Features
ï· Closed loop (compensated) current
transducer using the Hall effect
ï· Insulated plastic case recognized
according to UL 94-V0.
Special features
ï· TA = - 40°C .. + 70°C
ï· Potted.
Advantages
Accuracy - Dynamic performance data
X G Overall accuracy @ IPN , TA = 25°C
ï¥ L Linearity error
I
O
IO T
t
r
di/dt
f
Offset current @ I = 0, T = 25°C
P
A
Thermal drift of IO
- 25°C .. + 70°C
- 40°C .. - 25°C
Response time 1) @ 90 % of I
PN
di/dt accurately followed
Frequency bandwidth (- 1 dB)
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
R S Secondary coil resistance @ TA = 70°C
m
Mass
Standards
± 0.5
%
< 0.1
%
Typ Max
± 0.4 mA
± 0.3 ± 0.6 mA
± 0.4 ± 1.0 mA
<1
> 50
DC .. 150
µs
A/µs
kHz
- 40 .. + 70
°C
- 50 .. + 85
°C
25
ï
184
g
EN 50155
ï· Excellent accuracy
ï· Very good linearity
ï· Low temperature drift
ï· Optimized response time
ï· Wide frequency bandwidth
ï· No insertion losses
ï· High immunity to external
interference
ï· Current overload capability.
Applications
ï·ï Single or three phases inverter
ï· Propulsion and braking chopper
ï· Propulsion converter
ï· Auxiliary converter
ï· Battery charger.
Application domain
ï· Traction.
Note : 1) With a di/dt of 100 A/µs.
LEM
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
060911/3
page 1/3
www.lem.com
|
▷ |