English
Language : 

HAZ4000-SRU Datasheet, PDF (1/3 Pages) LEM – Current Transducers
Current Transducers HAZ 4000..20000-SRU
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I = 4000..20000 A
PN
VOUT = 0-10 V
(T-RMS DC)
Electrical data
Primary nominal
r.m.s. current
IPN (A)
4000
6000
10000
12000
14000
20000
Primary current
measuring range
IP (A)
± 4000
± 6000
± 10000
± 12000
± 14000
± 20000
Type
HAZ 4000-SRU
HAZ 6000-SRU
HAZ 10000-SRU
HAZ 12000-SRU
HAZ 14000-SRU
HAZ 20000-SRU
VC
IC
I
OC
R
IS
VOUT
ROUT
RL
Supply voltage (± 5 %)
± 15
Current consumption
± 30
Overload capacity
30,000
Isolation resistance @ 500 VDC
> 1000
Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C
0-10
Output internal resistance
approx. 100
Load resistance
> 10
V
mA
A
MΩ
V DC
Ω
kΩ
Accuracy - Dynamic performance data
X
εL
VOE
V
OH
ε VOT
TC
G
tr
f
Accuracy @ I , T = 25°C (without offset)
PN A
Linearity error 1) (0 .. ± IPN)
Electrical offset voltage, TA = 25°C, @ IP = 0
Hysteresis offset voltage @ I = 0;
P
after an excursion of 1 x IPN
Thermal drift of VOE
Thermal drift of the gain (% of reading)
Response time @ 90% of IPN
Frequency range, ±3 dB, small signal 2)
<±1
%
< ± 0.5 % of IPN
< ± 100 mV
< ± 12.5 mV
< ± 1 mV/K
< ± 0.05 %/K
< 400
ms
DC and 15 to 3kHz
General data
TA
Ambient operating temperature
T
Ambient storage temperature
S
Housing PBT 30% glassfiber
UL94 classification
m
Mass
Standards 3)
- 25 .. + 85 °C
- 30 .. + 90 °C
V0
approx. 6
kg
EN 50178:1997
Features
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• True-rms, 0-10V DC voltage output
• Isolation voltage 12kV Rms/ 50 Hz
/ 1 min
• Low power consumption
• Package in PBT meeting UL 94-V0
Advantages
• Easy mounting
• Small size and space savings
• Only one design for wide current
ratings range
• High immunity against external
interference
Applications
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Power supplies for welding and
telecom applications.
Application Domain
• Industrial
Notes : 1) Linearity data exclude the electrical offset.
2) To avoid excessive core heating.
3) Please consult characterisation report for more technical details and
application advice.
LEM
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
060428/2
Page 1/3
www.lem.com