Current Transducer HAX 500..2500-S
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 500..2500 A
VOUT= ± 4 V
Electrical data
Primary nominal
rms current
IPN (A)
500
600
850
1000
1200
1500
2000
2500
Primary current
measuring range 5)
IP (A)
± 1500
± 1800
± 2550
± 3000
± 3600
± 4500
± 5500
± 5500
Type
HAX 500-S
HAX 600-S
HAX 850-S
HAX 1000-S
HAX 1200-S
HAX 1500-S
HAX 2000-S
HAX 2500-S
RoHS since
date code
46137
planned
45350
45348
46138
46017
46100
46143
V
C
IC
IOC
RIS
V
OUT
ROUT
RL
Supply voltage (± 5 %) 5)
± 15
V
Current consumption
± 15
mA
Overload capacity
30,000
At
Isolation resistance @ 500 VDC
> 1000 MΩ
Output
voltage
(Analog)
@
±
I,
PN
R
L
=
10
kΩ,
T
A
=
25°C
± 4V ± 40
mV
Output internal resistance
approx. 100
Ω
Load resistance
>1
kΩ
Accuracy - Dynamic performance data
X
εL
VOE
V
OH
TCVOE
TCG
t
r
di/dt
f
Accuracy @ I , T = 25°C (without offset)
PN A
Linearity error 2) (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ I = 0;
P
after an excursion of 1 x I
PN
Temperature coefficient of VOE
Temperature coefficient of G (% of reading)
Response time @ 90% of I
P
di/dt accurately followed
Frequency bandwidth 3)(- 3 dB)
<±1
%
< ± 1 % of IPN
< ± 20
mV
< ± 30
mV
< ± 1 mV/K
< ± 0.1 %/K
<5
µs
> 50
A/µs
DC .. 25 kHz
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
m
Mass
Standards 4)
- 25 .. + 85 °C
- 25 .. + 85 °C
approx. 450
g
EN 50178: 1997
Features
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Isolation voltage 5000 V~
• Low power consumption
• Package in PBT meets UL 94-V0
Advantages
• Easy mounting
• Small size and space savings
• Only one design for wide current
ratings range
• High immunity against external
interference
Applications
• AC motor speed control
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Power supplies for welding, cable TV
and telecommunication applications.
Application Domain
• Industrial
Isolation characteristics
Vb
Rms rated voltage, safe separation
5001)
V
Vd
Rms voltage for AC isolation test, 50 Hz, 1 min
5
kV
dCp
Creepage distance
≥ 8.5
mm
Isolation material group
IIIa
Notes : 1) Pollution class 2, overvoltage category III
2) Linearity data exclude the electrical offset.
3) Please refer to derating curves in the technical file to avoid excessive
core heating at high frequency
4) Please consult characterisation report for more technical details and
application advice.
5) Operating at ±12V ≤ Vc < ±15V will reduce the measuring range.
060905/10
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.