HAS-50-S Datasheet, PDF (1/3 Pages) LEM – Current Transducer HAS 50 .. 600-S | |||
|
Current Transducer HAS 50 .. 600-S
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic separation between the primary circuit and the secondary
circuit.
IPN = 50 .. 600 A
Electrical data
Type
Primary nominal Primary current, RoHS since
rms current measuring range 1) date code
IPN (A)
HAS 50-S
50
IPM (A)
±150
45217
HAS 100-S
100
±300
45325
HAS 200-S
200
±600
45166
HAS 300-S
300
±900
45326
HAS 400-S
400
±900
45333
HAS 500-S
500
±900
45201
HAS 600-S
600
±900
45260
UC
Supply voltage (±5 %) 1)
±15
V
IC
Current consumption
±15
mA
RIS Insulation resistance @ 500 V DC
>1000
Mâ¦
Vout Output voltage (Analog) @ ±IPN, RL = 10 kâ¦, TA = 25 °C ±4
V
Rout Output internal resistance
approx
100
â¦
RL
Load resistance 2)
>1
kâ¦
Accuracy - Dynamic performance data
X
Accuracy @ IPN, TA = 25 °C (excluding offset)
<±1
% of IPN
εL
Linearity error 3) (0 .. ±IPN)
<±1
% of IPN
VOE Electrical offset voltage, TA = 25 °C
<±20
mV
VOH Hysteresis offset voltage @ IP = 0,
after an excursion of 1 à IPN <±20
mV
TCVOE Temperature coefficient of VOE HAS 50-S
<±2
mV/K
HAS 100 .. 600-S <±1
mV/K
TCVout Temperature coefficient of Vout (% of reading)
tr
Step response time to 90 % of IPN
di/dt di/dt accurately followed
<±0.1
<3
>50
%/K
µs
A/µs
BW Frequency bandwidth (-3 dB) 4)
DC .. 50
kHz
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
m
Mass
approx
Standards
-10 .. +80
°C
-25 .. +80
°C
60
g
EN 50178: 1997
UL 508: 2010
Features
ââ Hall effect measuring principle
ââ Insulating plastic case made of
polycarbonate PBT recognized
according to UL 94-V0.
Advantages
ââ Easy mounting
ââ Low power consumption
ââ Small size and space saving
ââ Only one design for wide current
ratings range
ââ High immunity to external
interference.
Applications
ââ AC variable speed drives
ââ Static converters for DC motor
drives
ââ Battery supplied applications
ââ Uninterruptible Power Supplies
(UPS)
ââ Switched Mode Power Supplies
(SMPS)
ââ Power supplies for welding
applications.
Application domain
ââ Industrial.
Notes: 1) Operating at ±12 V ⤠UC <±15 V will reduce the measuring range
2) If the customer uses 1 k⦠of the load resistor, the primary current has to be
limited as the nominal; To measure the full defined measuring range, the
load resistor should be at minimum 10 kâ¦
3) Linearity data exclude the electrical offset
4) Please refer to derating curves in the technical file to avoid excessive core
heating at high frequency.
N° 74.74.25.000.0, N° 74.74.34.000.0, N° 74.74.44.000.0, N° 74.74.46.000.0, N° 74.74.48.000.0, N° 74.74.50.000.0, N° 74.74.52.000.0 Page 1/3
30March2015/version 13
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
|
▷ |