English
Language : 

HAC100 Datasheet, PDF (1/3 Pages) LEM – Current Transducers
Current Transducers HAC 100..800-S IPN = 100 .. 800 A
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primary nominal
current rms
IPN (A)
100
200
300
400
500
600
800
Primary current
measuring range
IPM (A)
± 300
± 600
± 900
± 1200
± 1500
± 1800
± 1800
Type
HAC 100-S
HAC 200-S
HAC 300-S
HAC 400-S
HAC 500-S
HAC 600-S
HAC 800-S
RoHS since
date code
46256
46220
planned
46242
planned
46186
46219
VC
I
C
R
IS
VOUT
R
OUT
R
L
Supply voltage (± 5 %)
± 15
V
Current consumption HAC 100..300-S
< ± 18
mA
HAC 400..800-S
< ± 25
mA
Isolation resistance @ 500 VDC
> 1000 MΩ
Output voltage (Analog) @ ± IPN, RL = 10 kΩ, TA = 25°C ± 4
V
Output internal resistance
100
Ω
Load resistance
> 10
kΩ
Accuracy - Dynamic performance data
X
εL
VOE
V
OH
TCVOE
TCV
OUT
tr
BW
Accuracy @ IPN, TA = 25°C (excluding offset)
Linearity error (0 .. ± I )
PN
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ I = 0;
P
after an excursion of 1 x IPN
Temperature coefficient of VOE
Temperature coefficient of V (% of reading)
OUT
Response time to 90% of IPN step
Frequency bandwidth (- 3 dB)1)
< ± 1 % of IPN
< ± 1 % of I
PN
< ± 30
mV
< ± 35
mV
< ± 1 mV/K
< ± 0.1 %/K
<7
µs
DC .. 50 kHz
General data
T
Ambient operating temperature
A
TS
Ambient storage temperature
m
Mass
- 10 .. + 80 °C
- 15 .. + 85 °C
70
g
Features
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Isolation voltage 2500 V
• Low power consumption
• Extended measuring range (3 x IPN)
Advantages
• Easy mounting
• Small size and space saving
• Only one design for wide current
ratings range
• High immunity to external
interference.
Applications
• AC variable speed drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
Application domain
• Industrial
Note :
1) Derating is needed to avoid excessive core heating at high frequency.
0 6 111 4 / 7
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/3
www.lem.com