ALPHA400 Datasheet, PDF (9/10 Pages) DENSEI-LAMBDA – Modular Watt Box Multi-Output Power Supplies 250W/400W/600W/800W/1250W
Specifications (please read the instruction manual before design)
ⅥAlpha 1250 Common specification
Alpha1250-12
Alpha1250-24
1 Nominal Output Voltage
2 Maximum Output Current
3 Maximum Output Power
4 Efficiency (typ)
(*1)
5 Input Voltage Range
(*2)
6 Input Current (typ)
7 Output Voltage Accuracy
8 Output Voltage Range
(*3)
9 Maximum Ripple & Noise
(*4)
10 Maximum Line Regulation
11 Maximum Load Regulation
(*5)
12 Over Current Protection
(*6)
13 Over Voltage Protection
(*7)
14 Remote Sensing
15 Remote On/Off
16 Series / parallel operation
17 Inrush Current
(*8)
18 PFHC
19 Power Factor
20 Over Output Power Protection
21 Hold-up time (typ)
(*1)
22 Leakage Current
(*1)
23 Operating Temperature
24 Operating Humidity
25 Storage Temperature
26 Storage Humidity
27 Cooling
28 Withstand Voltage
29 Isolation Resistance
30 Vibration
31 Shock
32 Safety Standard
33 Conducted Emission
34 Radiated Emission
35 Immunity
36 Weight
37 Size (W x H x D)
12V
24V
104A
52A
1248W
1248W
80%
200 ~ 265VAC(47 ~ 63Hz)
7.0A: 230VAC AT 1248W
11.88 ~ 12.12V
23.76 ~ 24.24V
Fixed
240mV
480mV
60mV
72mV
240mV
480mV
105 ~ 112A
53 ~ 58A
16.2 ~ 18.6V
32.4 ~ 37.2V
Possible(Max 1V for total drop)
Available
Not available
40A max. (Ta=25˚C Cold start)
Built to meet EN61000-3-2 (PFHC Range : 200 ~ 255VAC)
230VAC: 0.95 at 1248W
more than 1260W
10ms
Less than 0.95mA
0 ~ +50˚C
30 ~ 90%Rh (No Dewdrop)
-30 ~ +85˚C
10 ~ 95%Rh (No Dewdrop)
Forced Air by Blower Fan
Input - FG: 1.5kVAC (20mA) for 1min. Input - Output: 3kVAC (20mA) for 1min.
More than 100MΩ Output - FG: 500VDC at 25˚C, 70%Rh
At no operating, 10 ~ 55Hz (Sweep for 1min) 19.6m/s2 Constant, X, Y, Z, 1hour each
Less than 196.1m/s2
Built to meet UL60950, CSA60950-00(C-UL), EN60950(SEMKO)
Built to meet EN55022-A, VCCI-A
Built to meet EN55022-A, VCCI-A
Built to meet EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-4 Level 4, EN61000-4-5 Level 3
3400g
175.5mm x 63mm x 279mm (Refer to Outline Drawing)
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
(*1) At 230VAC Nominal output voltage and maximum output current. Total output power 1248W (Ta=25˚C)
(*2) For cases where conformance to various safety specs are required, input voltage range will be 200 ~ 240VAC (50/60Hz).
(*3) Factory Programmed (Available for ×¢10% setting Range)
(*4) 100MHz B. W JEITA RC-9131 Method
(*5) When remote sense connected.
(*6) Constant Current Limit Auto recovery.
(*7) Output Shut Down Method Manual reset (Line recycle).
(*8) When resuming operation in less than 10 sec. after power failure at no load, soft start circuit will not limit the inrush current at turn - on.
Not applicable for the inrush current to Noise Filter less than 0.2 ms.