ALPHA400 Datasheet, PDF (6/10 Pages) DENSEI-LAMBDA – Modular Watt Box Multi-Output Power Supplies 250W/400W/600W/800W/1250W
Specifications (please read the instruction manual before design)
ⅥAlpha 400/600/800 Common specification
1 NUMBER of SLOTS
2 INPUT VOLTAGE RANGE
3 MAXIMUM TOTAL OUTPUT WATTAGE
4 INPUT CURRENT typ.
5 INRUSH CURRENT
6 HARMONICS CURRENT CONTROL
7 POWER FACTOR typ.
8 EFFICIENCY (typ.)
9 MISSING CYCLE HOLD UP TIME (typ.)
10 LEAKAGE CURRENT
11 OPERATING AMBIENT TEMPERATURE
12 OPERATING AMBIENT HUMIDITY
13 STORAGE AMBIENT TEMPERATURE
14 STORAGE AMBIENT HUMIDITY
15 COOLING
16 WITHSTAND VOLTAGE
17 INSULATION RESISTOR
18 VIBRATION
19 MECHANICAL SHOCK
20 SAFETY STANDARDS
21 CONDUCTED E.M.I.
22 RADIATED R.F.I.
23 NOISE IMMUNITY
24 WEIGHT (typ.)
25 SIZE (W x H x D)
Alpha400
Alpha600
Alpha800
5 Slots (7 channels max.)
5 Slots (7 channels max.)
7 Slots (14 channels max.)
85-265VAC(47-63Hz) 85-90VAC (required the output derating)
400W
600W
800W(1000W peak)
7A: 100VAC/3.5A: 200VAC at full load 10A: 100VAC/ 5A: 200VAC at full load 13A: 100VAC/ 6.5A: 200VAC at full load
20A max.
30A max.
40A max.
meet EN61000-3-2 (Harmonics current correction range: 85-255VAC)
0.99 (typ.): input 100VAC at full load / 0.95 (typ.): 230VAC at full load
75%: input 100/200VAC nominal outputs voltage at maximum total output power
minimum 16mS: input 100/200VAC nominal outputs voltage at maximum total output power
maximum 0.95mA at full load
0~+60°C (0-50°C : 100%, +60°C : 75%)
30~90%RH (no condensation)
-30~+85˚C
10~95%RH (no condensation)
Forced air cooling with internal fan
input - FG 1.5kVAC for one minute (20mA): input - output 3kVAC for one minute (20mA)
minimum 100M ohm (output - FG 500VDC. 25˚C. 70%RH)
Vibration cycles at 10-55Hz, sweep time for one minute, 19.6m/s2 constant, X,Y,Z axis on each side for one hour with no input.
maximum 196.1m/s2
Approved by UL1950, CSA950 (C-UL), EN60950(SEMKO), EN60601-1, UL2601-1, meet DENTORI
meets EN55022-class A, meet VCCI-class A
meets EN55022-class A, VCCI-classA
meets EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-4 Level4 and EN61000-4-5 Level 3
2100g
2500g
3400g
126.5 x 63 x 274.5mm
126.5 x 63 x 318.5mm
175.5 x 63 x 279mm
ⅥAlpha 400/600/800 Specification for Output Modules
Output Module name
ABCD
E
FG
H
MN
P
QR T
1. NUMBER of SLOTS
2111
1
22
1
11
1
122
2. RATED OUTPUT VOLTAGE
V 5 5 12 24 12 12 12 24 24 24 12 24 24 12 3.3 3.3 2
3. MAXIMUM OUTPUT CURRENT
A 60 25 16 8 8 8 33 25 5 5 8 5 5 8 25 60 60
4. OUTPUT VOLTAGE RANGE
V 4.5 4.5 5.0 18.0 5.0 5.0 10.0 18.0 18.0 18.0 5.0 18.0 18.0 5.0 2.7 2.7 1.8
-5.5 -5.5 -15.0 -28.0 -15.0 -15.0 -15.0 -28.0 -28.0 -28.0 -15.0 -28.0 -28.0 -15.0 -3.9 -3.9 -2.4
5. MAXIMUM OUTPUT RIPPLE
mV 100 100 240 480 240 240 240 480 480 480 240 480 480 240 100 100 100
AND NOISE VOLTAGE
(*1) P-P
6. MAXIMUM LINE REGULATION (*2) mV 25 25 60 72 60 60 60 72 72 72 60 72 72 60 25 25 25
7. MAXIMUM LOAD REGULATION (*3) mV 100 100 240 480 240 240 240 480 480 480 240 480 480 240 100 100 100
8. OVERLOAD CURRENT PROTECTION (*4) A 63.0 26.3 16.8 8.4 8.4 8.4 34.6 26.2 5.2 5.2 8.4 5.2 5.2 8.4 26.3 63.0 63.0
-78.0 -32.5 -20.8 -10.4 -10.4 -10.4 -42.9 -32.5 -5.8 -5.8 -10.4 -5.8 -5.8 -10.4 -32.5 -78.0 -78.0
9. OVER VOLTAGE PROTECTION (*5) V 6.3 6.3 16.2 32.4 16.2 16.2 16.2 32.4 32.4 32.4 16.2 32.4 32.4 16.2 4.1 4.1 2.71
-7.0 -7.0 -18.6 -37.2 -18.6 -18.6 -18.6 -37.2 -37.2 -37.2 -18.6 -37.2 -37.2 -18.6 -4.7 -4.7 -3.0
10. OPERATING AMBIENT TEMPERATURE 0~+60°C ( 0~+50°C : 100%, +60°C : 75% )
11. REMOTE SENSING
Available (without dual outputs module: E, H, P Module)
12. REMOTE ON/OFF CONTROL
Option I J: output inhibits on each output (TTL level)
OUTPUT INHIBIT CONTROL
MJ: output inhibits on all the outputs (TTL level)
13. SERIES OPERATION
Available (can be operated in series between each output of Output Module and dual Outputs Module)
14. PARALLEL OPERATION
Available (Please contact to Densei-Lambda before use in parallel operation of the Modules)
15. OUTPUT VOLTAGE MONITOR SIGNAL Option for I J Module: monitoring the output voltage up or down (TTL open collector)
16. INPUT VOLTAGE DETECTOR SIGNAL Option for M J Module: detecting the output of the active filter (TTL open collector)
(*1) 100MHz (measured by the Japanese Standard EIAJ RC-9131) (*4) Constant Current Auto-Reset (pre-set before shipment: fixed the limitation)
(*2) Input Voltage 85 - 265VAC at constant load
(*5) Shut Down method with Manual Reset (restart the input to be reset)
(*3) no-load to full-load, at constant input voltage (when use the remote sensing, the level will be the same as the line regulation.)