English
Language : 

U4431A Datasheet, PDF (7/10 Pages) Keysight Technologies – MIPI M-PHY Protocol Analyzer
07 | Keysight | U4431A MIPI M-PHY Protocol Analyzer - Data Sheet
U4431A – Performance Characteristics (Continued)
Triggering (Continued)
Real-time error detection
–– 8 b/10 b
–– Disparity
–– CRC
–– Flow control
Analysis
LED indicators
Traffic overview
Filters
Search
Command Line Packet Generator
Protocol version support
–– UniPro
–– UFS
–– Physical Layer
HS modes supported
PWM data rates (Series A and B), Mbps
–– G0
–– G1
–– G2
–– G3
–– G4
–– G5
–– G6
–– G7
Symbol lock time
–– HS-G1
–– HS-G2, HS-G3
Link width
Link mapping
Traffic class
Preemption support
CPort support
Automatic flow control
Endpoint support
Timing control
Voltage control
Error insertion
–– M-PHY
–– UniPro
–– UFS
User interface
Environmental specifications
Radiated emissions (RE)
Radiated immunity (RI)
Electrostatic discharge
Operating temperature
Storage temperature
Operating humidity
Storage humidity
Random vibration, Operating
Random vibration, Survival
Half sine shock
Trapezoidal shock
Operating altitude
Storage altitude
Operating magnetic field immunity
Safety
Yes
Yes
CRC32,16,5
Yes
Sub-link state and lane width
Packet count with occurrence navigation
User-defined packet and error filters
User-defined packet and error search
Unified Protocol (UniPro) 1.60
Universal Flash Storage (UFS) 2.0 (JESD220B)
M-PHY 3.0
G1 to G3
0.9, 1.1
5.2, 6.1
10.4, 12.1
20.8, 24.3
41.6, 48.6
83.2, 97.2
166, 194
499, 583
1 symbol, typical
< 128 symbols
1, 2, 3, or 4 links per sub-link
Manual width, static mapping
TC0
Not supported
1
Not supported
Host only
Fixed prepare, sync, and sleep/stall idle time. User-defined idle between packets
LA/HA only
8b/10b, disparity
CRC, incorrect reserved bits
User-defined payload via TCL script
User-defined TCL scripts with function library
CISPR 11/EN55001
EN/IEC 61000-4-3 frequency range at V/m
(EN/IEC 61000-4-2)+ discharge air/contact (kV)
Operating range: Min-max (°C)
Storage range: Non-operating min-max (°C)
Max % RH at temperature °C
Max % RH at temperature °C
5 to 500 Hz random, Grms
5 to 500 Hz random, Grms
2 mS half sine delta velocity m/sec (in/sec)
24 mS trapezoidal delta velocity m/sec (in/sec)
Kilo feet/kilo meters
Non-operating (kilo feet/kilo meters)
A/m rms
IEC 61010-1 (3rd edition)
Group 1 Class A
80 MHz to 2 GHz at 3 V/m; 2 to 2.7 GHz at1 V/m
8/4
+5 to +40
–40 to +70
80 at 40
90 at 65
0.21
2.09
1.6 (60)
8.00 (315)
10/3.1
15/4.6
30
Single fault condition