SCOPE SPECIFICATIONS[1]
Vertical System: Scope Channels
Bandwidth (–3 dB)
U1602B: DC to 20 MHz
U1604B: DC to 40 MHz
DC vertical gain accuracy
5 mV/div to 20 mV/div: ± 5% full scale
50 mV/div to 100 V/div: ± 3% full scale
Scope Channel Triggering
Trigger sensitivity
DC to 5 MHz: 0.8 divisions
U1602B: 5 MHz to 20 MHz – 1 division
U1604B: 5 MHz to 40 MHz – 1 division
SCOPE CHARACTERISTICS[2]
Acquisition: Scope Channels
Maximum sample rate
Equivalent sample rate
Vertical resolution
Maximum recording length:
Peak detection
Average
100 MSa/s per channel (50 s/div to 250 ns/div)3
200 MSa/s single channel and interleaved (125 ns/div)4
U1604B: 2.5 GSa/s (125 ns/div to 10 ns/div)
8 bits
U1602B/U1604B: Up to 125 000 points, viewable on screen with zoom function
5 ns
Selectable in average number of 2, 4, 8, 16, 32, 64, 128, 256
Vertical System: Scope Channels
Analog channels
Bandwidth (–3 dB)
AC coupled
Rise time
Single shot bandwidth
Vertical sensitivity
Maximum input
Offset/Dynamic range
Input impedance
Coupling
Channel 1 and Channel 2 simultaneous acquisition
U1602B: DC to 20 MHz
U1604B: DC to 40 MHz
< 10 Hz without probe
< 1 Hz with 10 MΩ 10:1 probe
U1602B: < 17.5 ns
U1604B: < 8.8 ns
U1602B: 20 MHz
U1604B: 40 MHz
5 mV/div to 100 V/div (1:1 scope probe)
50 mV/div to 1 kV/div (10:1 scope probe)
500 mV/div to 10 kV/div (100:1 scope probe)
CAT III 300 Vrms (up to 400 Hz) from terminal to ground
± 5 div
1 MΩ I I < 20 pF
AC, DC, GND
1. All speciications are warranted. Speciications are valid after a 30-minute warm-up period and within a range of ±10 ºC from irmware calibration
temperature.
2. All characteristics are typical performance values and are not warranted. Characteristics are valid after a 30-minute warm-up period and within a range of
±10 ºC from irmware calibration temperature.
3. Maximum sampling rates are shown here. Sampling rate will vary according to selected time base. For more information, please refer to User’s and
Service Guide.
4. 200 MS/s sampling rate is only available at 125 ns/div timebase
5. Number of points displayed will vary according to time base selected. For more information, refer to User’s and Service Guide