11 | Keysight | ISDB-T/Tmm X-Series Measurement Application N6155A & W6155A - Technical Overview
Description
PXA
MXA
EXA
CXA
Spectrum emission mask
3.0 MHz offset (RBW = 10 kHz)
Limit type: Manual; JEITA(ARIB-B31) according to P ≤ 0.025 W, 0.025 W < P ≤ 0.25 W, 0.25 W < P
≤ 2.5 W or P > 2.5 W: ABNT non-critical; ABNT sub-critical; ABNT-critical; ISDB-TSB
Dynamic range, relative
93.8 dB (99.1 dB typ)
87.6 dB (93.9 dB typ)
82.3 dB (89.5 dB typ)
79.7 dB (86.4 dB typ)
Sensitivity, absolute
–110.5 dB
(–114.5 dBm typ)
–106.5 dB
(–111.5 dBm typ)
–101.5 dB
(–107.5 dBm typ)
–98.5 dB
(–104.5 dBm typ)
Accuracy
Relative
± 0.08 dB
± 0.16 dB
± 0.16 dB
± 0.23 dB
Absolute, 20 to 30 °C
± 0.62 dB
(± 0.20 dB 95%)
± 0.88 dB
(± 0.23 dB 95%)
± 1.05 dB
(± 0.31 dB 95%)
± 1.53 dB
(± 0.64 dB 95%)
4.36 MHz offset (RBW = 10 kHz)
Dynamic range, relative
94.2 dB
(99.5 dB typ)
88.1 dB
(94.4 dB typ)
82.8 dB
(89.9 dB typ)
80.4 dB
(87.7 dB typ)
Sensitivity, absolute
–110.5 dB
(–114.5 dBm typ)
–106.5 dB
(–111.5 dBm typ)
–101.5 dB
(–107.5 dBm typ)
–98.5 dB
(–104.5 dBm typ)
Accuracy
Relative
± 0.01 dB
± 0.18 dB
± 0.18 dB
± 0.29 dB
Absolute
± 0.62 dB
(± 0.20 dB 95%)
± 0.88 dB
(± 0.23 dB 95%)
± 1.05 dB
(± 0.31 dB 95%)
± 1.53 dB
(± 0.64 dB 95%)
ISDB-T modulation accuracy
Segments = 13, mode 3, GI = 1/8, partial reception = off, layer A-C segment = 13, code rate = 3/4,
time interleaving I = 2, modualtion = 64QAM
ML1 = −20 dBm, 20 to 30 °C
EVM
Operating range
0 to 8%
0 to 8%
0 to 8%
0 to 8%
Floor
0.36% (EQ OFF)
0.66% (EQ OFF)
0.80% (EQ OFF)
0.99% (EQ Off)
Accuracy
from 0.40/0.66/0.80%
(PXA/MXA/EXA) to 1.2%
± 0.20%
± 0.30%
± 0.40%
from 1.2 to 2.0%
± 0.20%
± 0.20%
± 0.30%
from 2.0 to 8.0%
± 0.70%
± 0.70%
± 0.70%
MER
Operating range
≥ 22 dB
≥ 22 dB
≥ 22 dB
≥ 22 dB
Floor
49 dB (EQ Off)
44 dB (EQ Off)
42 dB (EQ Off)
40.1 dB (EQ Off)
Accuracy
from 38 to 48 dB
(PXA/MXA/EXA)
± 2.54 dB
± 2.68 dB
± 3.00 dB
from 34 to 38 dB
± 0.67 dB
± 1.16 dB
± 1.52 dB
from 22 to 34 dB
± 0.61 dB
± 0.73 dB
± 0.85 dB
Frequency error2
Range
–100 to 100 kHz
–100 to 100 kHz
–100 to 100 kHz
–100 to 100 kHz
Accuracy
± 10 Hz + tfa3
± 10 Hz + tfa3
± 10 Hz + tfa3
± 10 Hz + tfa3
Quad error
Range
–5 to 5 deg
–5 to 5 deg
–5 to 5 deg
–5 to 5 deg
Amplitude imbalance
Range
–1 to 1 dB
–1 to 1 dB
–1 to 1 dB
–1 to 1 dB
Channel impulse response (SFN
echo pattern)
(a) Selectable center and time/div
(b) Scale type by time or distance
(c) Results sorted by amplitude or time/distance
(d) Default echo search limit -35 dB and adjustable
(e) Adjustable FFT start position (0/8 to 8/8 GI), and MER metric displayed on the top of the view can be used as the
criteria to tune the FFT window
(f) Support pre-echo, post-echo, 0-dB echo, and out-of-GI echo scenarios
1.  ML (mixer level) is RF input power minus attenuation
2.  The accuracy specification applies at the EVM = 1%
3.  tfa = transmitter frequency × frequency reference accuracy