English
Language : 

W6153A Datasheet, PDF (11/15 Pages) Keysight Technologies – X-Series Measurement Application
11 | Keysight | N6153A & W6153A DVB-T/H with T2 X-Series Measurement Application - Technical Overview
Description
LDPC itineration times
Data
L1-pre
L1-post
MISO Tx1 only
MISO Tx2 only
MISO Tx1+Tx
Channel impulse response
(SISO-SFN and MISO-SFN
echo pattern)
PXA
MXA
EXA
CXA
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
Measurements same as SISO
Measurements same as SISO
(a) Combined data MER/EVM (rms)
(b) Combined L1-pre EVM/MER (rms)
(c) Combined L1-post EVM/MER (rms)
(d) Combined BER result
(e) Combined data per PLP (MER rms, EVM rms, Magnitude Error rms, Phase Error rms)
(f) Channel frequency response (Tx1)
(g) Channel frequency response (Tx2)
(h) Frequency error (Hz)
(i) Clock error (Hz)
(j) Tx power (dBm)
(a) Selectable center and time/div
(b) Scale type by Time or Distance
(c) Results sorted by Amplitude or Time/Distance
(d) Default echo search limit –35 dB and adjustable
(e) Adjustable FFT Start Position (0/8 to 8/8 GI), and MER metric displayed on the top of the view
can be used as the criteria to tune the FFT window
(f) Support pre-echo, post-echo, 0 dB echo and out-of-GI echo scenarios
(g) Cell ID (hex/dec) display
(h) Adjustable echo display, from MISO Tx1 group, or from MISO Tx2 group, or from MISO Tx1+Tx2
(dual trace, relative amplitude and delay display between Tx1 group and Tx2 group)
For a complete list of specifications refer to the appropriate specifications guide.
PXA:
MXA:
EXA:
CXA:
www.keysight.com/find/pxa/specifications
www.keysight.com/find/mxa/specifications
www.keysight.com/find/exa/specifications
www.keysight.com/find/cxa/specifications