English
Language : 

N5469A Datasheet, PDF (11/14 Pages) Keysight Technologies – MIL-STD 1553 Triggering
Make MIL-STD 1553 measurements in the ield under
battery operation
Keysight 6000 Series oscilloscopes provide an optional internal rechargeable lithium
ion battery that will enable 2+ hours without line power. Option BAT on 6000 Series
scopes was specifically designed for applications where line power is not available
and for when a handheld scopemeter lacks the needed measurement capability for
MIL-STD 1553 applications. The Keysight 6000 Series oscilloscopes offer the only
high-performance scope (up to 1 GHz bandwidth) with battery option on the market.
Figure 13. Keysight’s 6000 Series oscilloscopes are available with a battery option for
remote/field testing of MIL-STD 1553 applications.
Operating Characteristics and Ordering Information
Characteristics
MIL-Std 1553 Input Source
Triggering
Color-coded, hardware-accelerated
decode
Option 553 or N5469A
Analog channels 1 & 2 or 3 & 4 (using a differential active probe)
– Data Word Start
– Data Word Stop
– Command/Status Word Start
– Command/Status Word Stop
– Remote Terminal Address (hex)
– Remote Terminal Address (hex) + 11 Bits (hex or Binary)
– Parity Error
– Sync Error
– Manchester Error
– Base: HEX or Binary
– Command or Status Word (“C/S” in green)
– Remote Terminal Address (hex or binary digits in green)
– 11 Bits following RTA (hex or binary digits in green)
– Data Word (“D” in white)
– Data Word Bits (hex or binary digits in white)
– Parity Error (entire decoded word in red)
– Synchronization Error (“Sync” in red)
– Manchester Error (“Manch“ in red)
11