C971U472MZWDAA7317 Datasheet, PDF (8/16 Pages) Kemet Corporation – Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Radial Leaded Ceramic Disc Capacitors
Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Table 2 – Performance & Reliability: Test Methods and Conditions cont'd
Item
Appearance
Capacitance
Change
High
Temperature
Life
IR
Dielectric
Strength
Flame Test
Specification
No visual defect
Y5P, Y5V and Y5U: Within ±20%
SL: Within ±3 or ±0.3 pF,
whichever is larger.
3,000 MΩ minimum
SL: 1,000 MΩ minimum
No failures
The capacitor flame extinguishes as
follows:
Cycle
1~4
5
Time
30 seconds
maximum
60 seconds
maximum
Test Method
Impulse Voltage: Each individual capacitor is subjected to three 5
kv impulses prior to life testing.
Vp
UPR
0.9Vp
UPP
0.5Vp
Cx tr td
(uF) (uS) (uS)
0.01 1.2 46
0.1 1.5 47
tr
td
Time
Capacitors are placed in a circulating air oven for a period of
1,000 hours. The air in the oven is maintained at a temperature of
125°C ±2 throughout the test. The capacitors are subjected to AC
510 Vrms. Each hour the voltage is increased to 1,000 Vrms for
0.1 seconds.
The capacitor is exposed to a flame for 15 seconds and then
removed for 15 seconds. This test is repeated for 5 cycles.
Capacitor
Flame
76
38 127
Gas Burner
20º
(Unit:mm)
The capacitors are individually wrapped in at least one, but not
more than two, complete layers of cheesecloth. They are then
subjected to 20 discharges. The interval between successive
discharges is 5 seconds. The VAC is maintained for 2 minutes
after the last discharge.
S1
F L1 L2
R
C1 C2 C3 CX
Ct
Vt
Tr S2 Vac L3
L4
Active Flammability
The cheesecloth should not ignite.
Oscilloscope
C1, 2
1 μF ±10%
L1-4 1.5 Mh ±20% 16A Rod core choke
R
100±2%
Ct
3 μF ±5% 10 kV
F
Fuse, Rated 10A
C3
0.033 μF ±5% 10 kV
Cx
Test capacitor
VAC
VR ±5%
VR
Rated Voltage
Vt Voltage applied to Ct
Vx
5kV
time
1 “Room Condition” is defined as follows: Temperature: 15 ~ 35°C/Humidity: 45 ~ 75%/Atmospheric Pressure: 86 ~ 106 kPa.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017 8