English
Language : 

EXV226M6R3A9BAA Datasheet, PDF (6/18 Pages) Kemet Corporation – Surface Mount Aluminum Electrolytic Capacitors
Surface Mount Aluminum Electrolytic Capacitors – EXV Series, +105°C
Mounting Positions (Safety Vent)
In operation, electrolytic capacitors will always conduct a leakage current which causes electrolysis. The oxygen produced by
electrolysis will regenerate the dielectric layer but, at the same time, the hydrogen released may cause the internal pressure
of the capacitor to increase. The overpressure vent (safety vent) ensures that the gas can escape when the pressure reaches
a certain value. All mounting positions must allow the safety vent to work properly.
Installing
• A general principle is that lower-use temperatures result in a longer, useful life of the capacitor. For this reason, it should
be ensured that electrolytic capacitors are placed away from heat-emitting components. Adequate space should be
allowed between components for cooling air to circulate, particularly when high ripple current loads are applied. In any
case, the maximum category temperature must not be exceeded.
• Do not deform the case of capacitors or use capacitors with a deformed case.
• Verify that the connections of the capacitors are able to insert on the board without excessive mechanical force.
• If the capacitors require mounting through additional means, the recommended mounting accessories shall be used.
• Verify the correct polarization of the capacitor on the board.
• Verify that the space around the pressure relief device is according to the following guideline:
Case Diameter
≤ 16 mm
> 16 to ≤ 40 mm
> 40 mm
Space Around Safety Vent
> 2 mm
> 3 mm
> 5 mm
It is recommended that capacitors always be mounted with the safety device uppermost or in the upper part of the capacitor.
• If the capacitors are stored for a long time, the leakage current must be verified. If the leakage current is superior to the
value listed in this catalog, the capacitors must be reformed. In this case, they can be reformed by application of the rated
voltage through a series resistor approximately 1 kΩ for capacitors with VR ≤ 160 V (5 W resistor) and 10 kΩ for the other
rated voltages.
• In the case of capacitors connected in series, a suitable voltage sharing must be used.
In the case of balancing resistors, the approximate resistance value can be calculated as: R = 60/C
KEMET recommends, nevertheless, to ensure that the voltage across each capacitor does not exceed its rated voltage.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
A4003_EXV • 12/2/2016 6