English
Language : 

CPC7583 Datasheet, PDF (8/19 Pages) Clare, Inc. – Line Card Access Switch
INTEGRATED CIRCUITS DIVISION
CPC7583
1.6.4 TESTOUT Switches, SW5 and SW6
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
Off-state leakage current
+25° C
VSW (differential) = -320 V to gnd
VSW (differential) = +260 V to -60 V
0.1
+85° C
VSW (differential) = -330 V to gnd
VSW (differential) = +260 V to -60 V
ISW
-
0.3
1
A
-40° C
VSW (differential) = -310 V to gnd
VSW (differential) = +250 V to -60 V
0.1
RON
+25° C
35
-
+85° C
-40° C
ISW(on) = ±10 mA, ±40 mA
RON
-
50
70

26
-
DC current limit
+25° C
-
140
-
+85° C
VSW (on) = ±10 V
80
100
-
mA
-40° C
-
210
250
Break switches in on state, ringing
ISW
Dynamic current limit switches off, apply ±1 kV at
(t 0.5 s)
10x1000 s pulse, with appropriate
-
2.5
-
A
secondary protection in place.
Logic input to switch output isolation
+25° C
VSW (TTESTout, TLINE, RTESTout, RLINE)
= ±320 V, logic inputs = gnd
ISW
-
0.1
1
A
+85° C
VSW (TTESTout, TLINE, RTESTout, RLINE)
= ±330 V, logic inputs = gnd
ISW
-
0.3
1
A
-40° C
VSW (TTESTout, TLINE, RTESTout, RLINE)
= ±310 V, logic inputs = gnd
ISW
-
0.1
1
A
dv/dt sensitivity
-
-
200
-
V/s
8
www.ixysic.com
R07