CPC7592 Datasheet, PDF (7/19 Pages) Clare, Inc. – Line Card Access Switch | |||
|
◁ |
INTEGRATED CIRCUITS DIVISION
CPC7592
1.6.4 Test Switches, SW5 and SW6
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
VSW1 (differential) = TLINE to TBAT
VSW2 (differential) = RLINE to RBAT
All-Off state.
+25ï° C,
VSW (differential) = -320 V to gnd
0.1
Off-State
VSW (differential) = +260 V to -60 V
Leakage Current
+85ï° C,
VSW (differential) = -330 V to gnd
ISW
-
0.3
1
ïA
VSW (differential) = +270 V to -60 V
-40ï° C,
VSW (differential) = -310 V to gnd
0.1
VSW (differential) = +250 V to -60 V
ISW(on) = ±10 mA, ±40 mA,
RBAT and TBAT = -2 V
On Resistance
+25ï° C
38
-
+85ï° C
-40ï° C
RON
-
46
70
ï
28
-
DC current limit
VSW (on) = ±10 V, +25ï° C
VSW (on) = ±10 V, +85ï° C
-
175
-
ISW
80
110
mA
VSW (on) = ±10 V, -40ï° C
-
210
250
Dynamic current limit
(t = <0.5 ïs)
Break switches on, all other switches
off. Apply ±1 kV 10x1000 ïs pulse with
appropriate protection in place.
ISW
-
2.5
-
A
+25ï° C, Logic inputs = gnd,
VSW (TLINE, RLINE) = ±320 V
-
0.1
Logic input to switch
output isolation
+85ï° C, Logic inputs = gnd,
VSW (TLINE, RLINE) = ±330 V
ISW
-
0.3
1
ïA
-40ï° C, Logic inputs = gnd,
VSW (TLINE, RLINE) = ±310 V
-
0.1
dV/dt sensitivity
-
-
-
500
-
V/ïs
R04
www.ixysic.com