1.6 Switch Specifications
1.6.1 Break Switches, SW1 and SW2
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
VSW1 (differential) = TLINE to TBAT
VSW2 (differential) = RLINE to RBAT
All-Off state.
+25 C,
VSW (differential) = -320V to gnd
0.1
Off-State
VSW (differential) = +260V to -60V
Leakage Current
+85 C,
VSW (differential) = -330V to gnd
ISW
-
0.3
1
A
VSW (differential) = +270V to -60V
-40 C,
VSW (differential) = -310V to gnd
0.1
VSW (differential) = +250V to -60V
ISW(on) = ±10 mA, ±40 mA,
RBAT and TBAT = -2V
On Resistance
+25 C
14.5
-
+85 C
RON
-
20.5
28

-40 C
10.5
-
On-Resistance
Matching
Per SW1 & SW2 On-Resistance test
conditions.
RON
-
0.15
0.8

VSW (on) = ±10V, +25 C
Low Frequency Current
Limit
VSW (on) = ±10V, +85 C
VSW (on) = ±10V, -40 C
-
300
-
ISW
80
160
mA
-
400
425
High Frequency
Break switches on, all other switches
Dynamic Current Limit off. Apply ±1kV 10x1000 s pulse with
ISW
-
2.5
-
A
(t  0.5 s)
appropriate protection in place.
+25 C, Logic inputs = gnd,
VSW (TLINE, RLINE) = ±320V
-
0.1
Switch Outputs to Logic +85 C, Logic inputs = gnd,
Input Isolation
VSW (TLINE, RLINE) = ±330V
ISW
-
0.3
1
A
-40 C, Logic inputs = gnd,
VSW (TLINE, RLINE) = ±310V
-
0.1
100VPP Square Wave, 100Hz
Transient Immunity
(Not production tested - limits are
dV/dt
1500
2100
-
V/s
guaranteed by design and quality
control sampling audits.)
4
www.ixysic.com