1.6 Switch Specifications
1.6.1 Break Switches, SW1 and SW2
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
VSW1 (differential) = TLINE to TBAT
VSW2 (differential) = RLINE to RBAT
All-Off state.
+25ï° C,
VSW (differential) = -320V to gnd
0.1
Off-State
VSW (differential) = +260V to -60V
Leakage Current
+85ï° C,
VSW (differential) = -330V to gnd
ISW
-
0.3
1
ïA
VSW (differential) = +270V to -60V
-40ï° C,
VSW (differential) = -310V to gnd
0.1
VSW (differential) = +250V to -60V
ISW(on) = ±10 mA, ±40 mA,
RBAT and TBAT = -2V
On Resistance
+25ï° C
14.5
-
+85ï° C
RON
-
20.5
28
ï
-40ï° C
10.5
-
On-Resistance
Matching
Per SW1 & SW2 On-Resistance test
conditions.
ïRON
-
0.15
0.8
ï
VSW (on) = ±10V, +25ï° C
Low Frequency Current
Limit
VSW (on) = ±10V, +85ï° C
VSW (on) = ±10V, -40ï° C
-
300
-
ISW
80
160
mA
-
400
425
High Frequency
Break switches on, all other switches
Dynamic Current Limit off. Apply ±1kV 10x1000 ïs pulse with
ISW
-
2.5
-
A
(t ï£ 0.5 ïs)
appropriate protection in place.
+25ï° C, Logic inputs = gnd,
VSW (TLINE, RLINE) = ±320V
-
0.1
Switch Outputs to Logic +85ï° C, Logic inputs = gnd,
Input Isolation
VSW (TLINE, RLINE) = ±330V
ISW
-
0.3
1
ïA
-40ï° C, Logic inputs = gnd,
VSW (TLINE, RLINE) = ±310V
-
0.1
100VPP Square Wave, 100Hz
Transient Immunity
(Not production tested - limits are
dV/dt
1500
2100
-
V/ïs
guaranteed by design and quality
control sampling audits.)
4
www.ixysic.com
R01
|
▷ |