English
Language : 

CPC7691 Datasheet, PDF (4/16 Pages) Clare, Inc. – Line Card Access Switch
INTEGRATED CIRCUITS DIVISION
CPC7691
1.6 Switch Specifications
1.6.1 Break Switches: SW1 and SW2
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
VSW1 (differential) = TLINE to TBAT
VSW2 (differential) = RLINE to RBAT
All-Off state.
+25C,
VSW (differential) = -320V to GND
0.1
Off-State
VSW (differential) = +260V to -60V
Leakage Current
+85C,
VSW (differential) = -330V to GND
ISW
-
0.3
1
A
VSW (differential) = +270V to -60V
-40C,
VSW (differential) = -310V to GND
0.1
VSW (differential) = +250V to -60V
ISW(on) = ±10 mA, ±40 mA,
RBAT and TBAT = -2V
On-Resistance
+25C
14.5
-
+85C
-40C
RON
-
20.5
28

10.5
-
On-Resistance
Matching
Per SW1 & SW2 On-Resistance test
conditions
RON
-
0.15
0.8

VSW (on) = ±10V
DC current limit
+25C
+85C
-40C
-
300
ISW
80
160
-
mA
-
400
425
Dynamic current limit
(t  0.5 s)
Break switches on, all other switches
off. Apply ±1 kV 10x1000 s pulse with
appropriate protection in place.
ISW
-
2.5
-
A
Logic inputs = GND
Logic input to switch +25C, VSW (TLINE, RLINE) = ±320V
-
0.1
output isolation
+85C, VSW (TLINE, RLINE) = ±330V
ISW
-
0.3
1
A
-40C, VSW (TLINE, RLINE) = ±310V
-
0.1
100VPP Square Wave, 100Hz
Transient Immunity
(Not production tested - limits are
dV/dt
1500
2100
-
V/s
guaranteed by design and quality
control sampling audits.)
4
www.ixysic.com
R01