English
Language : 

CPC1963 Datasheet, PDF (4/7 Pages) Clare, Inc. – AC Power Switch
INTEGRATED CIRCUITS DIVISION
1.2
1.0
0.8
0.6
0.4
0.2
0
-40
Load Current, Free Air
R4JA=60 ºC/W
0
55
Temperature (ºC)
PERFORMANCE DATA*
Typical Blocking Voltage
vs. Temperature
670
660
650
640
630
620
610
85
25
40
55
70
85
Temperature (ºC)
CPC1963
0.278
0.276
0.274
0.272
0.270
0.268
0.266
0.264
Typical Leakage vs. Temperature
(VL=600VP)
25
40
55
70
85
Temperature (ºC)
1400
1200
1000
800
600
400
200
0
Typical dV/dt vs. Temperature
Vo
63%
0
25
50
Temperature (ºC)
10%
85
dV/dt Method
Vo = 300V
dV 0.63 x 300V 189
dt
RC
RC
In accordance with
EIA/NARM Standards
RS-443 for Solid State Relays
RC
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please
contact our application department.
4
www.ixysic.com
R06