English
Language : 

CPC1963 Datasheet, PDF (2/7 Pages) Clare, Inc. – AC Power Switch
INTEGRATED CIRCUITS DIVISION
Absolute Maximum Ratings @ 25ºC
Parameter
Blocking Voltage
Reverse Input Voltage
Ratings Units
600
VP
5
V
Input Control Current
Peak (10ms)
Input Power Dissipation 1
Total Package Dissipation 2
50
mA
1
A
150
mW
800
mW
Isolation Voltage, Input to Output
Operational Temperature
3750
Vrms
-40 to +85 °C
Storage Temperature
-40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
CPC1963
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics @ 25ºC
Parameter
Output Characteristics
Conditions
Operating Voltage Range
Load Current, Continuous
Off State Leakage Current
VT
VL=120Vrms
V = 600V
On-State Voltage Drop
Critical Rate of Rise 3
IL=500 mArms
-
Switching Speeds
Turn-on
Turn-off
Zero-Cross Turn-On Voltage 1
IF=5 mA
1st half-cycle
Subsequent half-cycle
Operating Frequency
-
Load Power Factor for Guaranteed Turn-On 2
-
Input Characteristics
Input Control Current to Activate 4
-
Input Drop-out Voltage
-
Input Voltage Drop
Reverse Input Current
Common Characteristics
IF=5mA
VR=5V
Input to Output Capacitance
-
1 Zero Cross 1st half-cycle @ <100Hz
2 Snubber circuits may be required at low power factors.
3 Tested in accordance with EIA/NARM standard RS-443.
4 For high noise environments use at least 10mA LED current.
Symbol
-
IL
ILEAK
VON
dV/dt
ton
toff
-
PF
IF
VF
IR
CI/O
Min
Typ Max Units
20
-
0.005
-
-
-
-
-
1000
-
260
Vrms
0.5
Arms
1
mA
1.4
Vrms
-
V/µs
-
-
0.5
cycles
-
-
0.5
-
2
10
V
-
1
-
20
-
500
Hz
0.25
-
-
-
-
0.23
5
mA
0.8
-
-
V
0.9
1.2
1.4
V
-
-
10
µA
-
3
-
pF
2
www.ixysic.com
R06