English
Language : 

LCA110 Datasheet, PDF (2/7 Pages) Clare, Inc. – Single Pole OptoMOS Relay
INTEGRATED CIRCUITS DIVISION
Absolute Maximum Ratings @ 25ºC
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation 1
Total Power Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Ratings
350
5
50
1
150
800
3750
-40 to +85
-40 to +125
Units
VP
V
mA
A
mW
mW
Vrms
°C
°C
LCA110
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics @ 25ºC
Parameter
Output Characteristics
Load Current
AC/DC Configuration, Continuous 1
DC Configuration, Continuous 1
Peak
On-Resistance 2
AC/DC Configuration
DC Configuration
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Input Characteristics
Input Control Current to Activate
Input Control Current to Deactivate
Input Voltage Drop
Reverse Input Current
Common Characteristics
Capacitance, Input to Output
Conditions
Symbol
Min
Typ
Max
Units
-
-
t=10ms
-
IL
-
ILPK
-
-
120
mArms & mADC
-
200
mADC
-
350
mA
IL=120mA
IL=200mA
RON
-
-
23
7
35
10

VL=350VP
ILEAK
-
-
1
µA
IF = 5mA, VL = 10V
ton
toff
-
-
-
-
3
3
ms
ms
VL=50V, f=1MHz
COUT
-
25
-
pF
IL = 120mA
IF
-
-
2
mA
-
IF
0.4
-
-
mA
IF = 5mA
VF
0.9
1.2
1.4
V
VR = 5V
IR
-
-
10
µA
-
CI/O
-
3
-
pF
1 If both poles operate, then the load current must be derated so that the package power dissipation value is not exceeded.
2 Measurement taken within 1 second of on-time.
2
www.ixysic.com
R12