LCA110 Datasheet, PDF (1/7 Pages) Clare, Inc. – Single Pole OptoMOS Relay | |||
|
INTEGRATED CIRCUITS DIVISION
Parameter
Blocking Voltage
Load Current
On-Resistance (max)
Ratings
350
120
35
Units
VP
mArms & mADC
ï
Features
⢠3750Vrms Input/Output Isolation
⢠Low Drive Power Requirements (TTL/CMOS
Compatible)
⢠High Reliability
⢠Arc-Free With No Snubbing Circuits
⢠No EMI/RFI Generation
⢠Small 6-Pin Package
⢠Machine Insertable, Wave Solderable
⢠Surface Mount Tape & Reel Version Available
⢠V-0 Flammability Classification Rating
Applications
⢠Instrumentation
⢠Multiplexers
⢠Data Acquisition
⢠Electronic Switching
⢠I/O Subsystems
⢠Meters (Watt-Hour, Water, Gas)
⢠Medical EquipmentâPatient/Equipment Isolation
⢠Security
⢠Aerospace
⢠Industrial Controls
LCA110
Single-Pole, Normally Open
OptoMOS® Relay
Description
The LCA110 is a normally open (1-Form-A) Solid
State Relay which uses optically coupled MOSFET
technology to provide 3750Vrms of input to output
isolation.
Its optically coupled outputs, which use the patented
OptoMOS architecture, are controlled by a highly
efficient GaAIAs infrared LED.
The LCA110 can be used to replace mechanical
relays, and offers the superior reliability associated with
semiconductor devices.
Approvals
⢠UL Recognized Component: File E76270
⢠CSA Certified Component: Certificate 1175739
⢠EN/IEC 60950-1 Certified Component:
TUV Certificate B 09 07 49410 004
Ordering Information
Part #
LCA110
LCA110S
LCA110STR
Description
6-Pin DIP (50/Tube)
6-Pin Surface Mount (50/Tube)
6-Pin Surface Mount (1,000/Reel)
Pin Configuration
AC/DC Configuration
1
+ Control
2
- Control
3
NC
6
Load
5
Do Not Use
4
Load
DC Only Configuration
1
6
+ Control
2
5
- Control
3
4
NC
+ Load
- Load
Switching Characteristics of
Normally Open Devices
Form-A
IF
I
LOAD
90%
ton
10%
toff
Pb
e3
DS-LCA110-R12
www.ixysic.com