English
Language : 

CPC40055ST Datasheet, PDF (2/8 Pages) IXYS Corporation – AC Power Switch
INTEGRATED CIRCUITS DIVISION
CPC40055ST
1 .Specifications
1.1 Absolute Maximum Ratings @ 25°C
Symbol
Min Max
Blocking Voltage
-
800
Reverse Input Voltage
-
5
Input Control Current
-
50
Peak (10ms)
-
1
Input Power Dissipation 1
-
150
Total Power Dissipation 2
-
4.4
I2t for Fusing
(1/2 Sine Wave, 60Hz)
-
200
Isolation Voltage, Input to Output
60 Seconds
-
2500
ESD, Human Body Model
-
4
Junction Temperature (TJ)
Operational Temperature
-
150
- 40 +85
Storage Temperature
- 40 +125
1 Derate linearly 1.33mW / °C.
2 Free air, no heat sink.
Units
VP
V
mA
A
mW
W
A2s
Vrms
kV
°C
°C
°C
Absolute maximum ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
1.2 Electrical Characteristics @ 25°C
Parameter
Conditions
Output Characteristics
Load Current
Continuous
Continuous
Maximum Surge Current
No Heat Sink, VL=20-280Vrms
TC=25°C
1/2 Sine Wave, 60Hz
Off-State Leakage Current
On-State Voltage Drop
Off-State dV/dt
Switching Speeds
VL=800V
IL=2AP
IF=0mA
Turn-On
Turn-Off
IF=5mA
Zero-Cross Turn-On Voltage 1
1st half-cycle
subsequent half-cycle
Holding Current
-
Latching Current
-
Operating Frequency
Load Power Factor for Guaranteed Turn-On 2
Input Characteristics
LED Current to Activate 3
Input Voltage to Deactivate
-
f=60Hz
IL=1A Resistive, f=60Hz
-
Input Voltage Drop
Reverse Input Current
Input/Output Characteristics
IF=5mA
VR=5V
Capacitance, Input-to-Output
-
Symbol
IL
IP
ILEAK
-
dV/dt
ton
toff
-
-
IH
IL
-
PF
IF
-
VF
IR
CI/O
Minimum Typical Maximum Units
0.1
-
0.1
-
-
-
-
-
-
0.85
1000
-
-
-
-
-
-
6.8
-
-
-
-
-
-
20
-
0.25
-
-
-
0.8
-
0.9
1.2
-
-
-
-
5
40
Arms
150
A
100
AP
1.1
VP
-
V/s
0.5
cycles
0.5
20
V
5
50
mA
75
mA
500
Hz
-
-
5
mA
-
V
1.4
V
10
A
3
pF
1 Zero-cross first half-cycle @ < 100Hz.
2 Snubber circuits may be required at low power factors.
3 For high-noise environments, or high-frequency operation (>60Hz), or for applications with a high inductive load, use IF 10mA.
R03
www.ixysic.com
2