English
Language : 

CPC1979 Datasheet, PDF (2/7 Pages) Clare, Inc. – ISOPLUS™-264 Power Relay
INTEGRATED CIRCUITS DIVISION
1 Specifications
1.1 Absolute Maximum Ratings @ 25°C
Symbol
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
Ratings
600
5
100
1
150
2500
-40 to +85
-40 to +125
Units
VP
V
mA
A
mW
Vrms
°C
°C
CPC1979
Absolute maximum ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
1.2 Electrical Characteristics @ 25°C
Parameter
Output Characteristics
Load Current 1
Peak
Continuous
Continuous
Continuous
On-Resistance 2
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Input Characteristics
Input Control Current to Activate 3
Input Control Current to Deactivate
Input Voltage Drop
Reverse Input Current
Input/Output Characteristics
Capacitance, Input-to-Output
Conditions
t 10ms
No Heat Sink
TC=25°C
TC=99°C
IF=10mA, IL=1A
VL=600VP
IF=20mA, VL=10V
VL=25V, f=1MHz
IL=1A
-
IF=5mA
VR=5V
-
Symbol Minimum Typical Maximum
Units
IL
IL(99)
RON
ILEAK
ton
toff
Cout
IF
IF
VF
IR
CI/O
20
AP
1.4
-
-
14.5
Arms / ADC
1.7
-
0.59
0.75

-
-
1
A
-
8
25
ms
-
0.2
5
-
700
-
pF
-
-
10
mA
0.6
-
-
mA
0.9
1.2
1.4
V
-
-
10
A
-
1
-
pF
1 Higher load currents possible with proper heat sinking.
2 Measurement taken within 1 second of on-time.
3 For applications requiring high temperature operation (TC > 60ºC) an LED drive current of 20mA is recommended.
R09
www.ixysic.com
2