English
Language : 

MEA75-12 Datasheet, PDF (1/2 Pages) IXYS Corporation – Fast Recovery Epitaxial Diode (FRED) Module
Fast Recovery
Epitaxial Diode
(FRED) Module
Preliminary data
VRSM
V
1200
VRRM
V
1200
Type
MEA75-12 DA
123
MEA 75-12 DA
MEK 75-12 DA
MEE 75-12 DA
VRRM = 1200 V
IFAV = 75 A
trr = 250 ns
MEK 75-12 DA
123
MEE 75-12 DA
123
TO-240 AA
3
2
1
Symbol
IFRMS
IFAV
IFRM
IFSM
I2t
TVJ
Tstg
THmax
Ptot
VISOL
Md
dS
dA
a
Weight
Symbol
IR
VF
VT0
rT
RthJH
RthJC
trr
IRM
Test Conditions
Tcase= 75 °C
Tcase= 75 °C; rectangular, d = 0.5
tP < 10 µs; rep. rating, pulse width limited by TVJM
TVJ = 45°C; t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 150°C; t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 45°C; t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 150°C; t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
Tcase = 25°C
50/60 Hz, RMS t = 1 min
IISOL ≤ 1 mA
t=1s
Mounting torque (M5)
Terminal connection torque (M5)
Creep distance on surface
Strike distance through air
Maximum allowable acceleration
Maximum Ratings
107 A
75 A
TBD A
1200 A
1300 A
1080 A
1170 A
7200 A2s
7100 A2s
5800 A2s
5700 A2s
-40...+150 °C
-40...+125 °C
110 °C
280 W
3000 V~
3600 V~
2.50-4/22-35 Nm/lb.in.
2.50-4/22-35 Nm/lb.in.
12.7 mm
9.6 mm
50 m/s2
90 g
Test Conditions
TVJ = 25°C
TVJ = 25°C
TVJ = 125°C
VR = VRRM
VR = 0.8 • VRRM
VR = 0.8 • VRRM
IF = 100 A;
IF = 300 A;
TVJ = 125°C
TVJ = 25°C
TVJ = 125°C
TVJ = 25°C
For power-loss calculations only
DC current
DC current
IF = 150 A
VR = 600 V
-di/dt = 200 A/µs
TVJ = 100°C
TVJ = 25°C
TVJ = 100°C
Characteristic Values (per diode)
typ.
max.
2 mA
0.5 mA
34 mA
1.85 V
2.17 V
2.58 V
2.64 V
1.48 V
3.65 mΩ
0.550 K/W
0.450 K/W
250
300 ns
22 A
33 A
Features
q International standard package
with DCB ceramic base plate
q Planar passivated chips
q Short recovery time
q Low switching losses
q Soft recovery behaviour
q Isolation voltage 3600 V~
q UL registered E 72873
Applications
q Antiparallel diode for high frequency
switching devices
q Free wheeling diode in converters
and motor control circuits
q Inductive heating and melting
q Uninterruptible power supplies (UPS)
q Ultrasonic cleaners and welders
Advantages
q High reliability circuit operation
q Low voltage peaks for reduced
protection circuits
q Low noise switching
q Low losses
Dimensions in mm (1 mm = 0.0394")
Data according to IEC 60747
IXYS reserves the right to change limits, test conditions and dimensions
© 2000 IXYS All rights reserved
D6 - 5