M3H2803R3S_16 Datasheet, PDF (5/12 Pages) International Rectifier – HYBRID-HIGH RELIABILITY RADIATION HARDENED DC-DC CONVERTER
M3H-SERIES
(+28V Input, Single/Dual Output)
Electrical Performance Characteristics (continued)
Parameter
Recovery time,
step load changes (TTLD)
Group A
Subgroup
4,5,6
Conditions
-55°C TC  +85°C
VIN = 28V DC ± 5%, CL = 0
unless otherwise specified
Half Load to/from Full Load,
Notes 4,9,10
Limits
Min Nom
Output response to
step line changes (VTLN)
Recovery time,
step line changes (TTLN)
Turn-on Response
Overshoot (VOS)
Turn-on Delay (TDLY)
Overshoot (VOS)
Turn-on Delay (TDLY)
Capacitive Load (CL)
M3H2803R3S
M3H2805S
M3H2005R2S
M3H2812S
M3H2815S
M3H2805D
M3H2812D
M3H2815D
Line Rejection
Isolation
Device Weight
4,5,6
4,5,6
4,5,6
4,5,6
18V to/from 40V
IOUT = 100% rated load, Notes 1,4,11
18V to/from 40V
IOUT = 100% rated load, Notes 1,4,10,11
No Load, Full Load for Dual
Notes 4,12
20 % Load, Full Load for Single
Notes 4,12
-300
2.0
2.0
IOUT = 100% rated load
No effect on DC performance
1
Notes 1, 4, 7
Each output on duals
1
IOUT = 100% rated load
DC to 50kHz, Notes 1, 4
40
50
1
Input to Output or Any Pin to Case
except pin 3, test @ 500VDC
100
MTBF
MIL-HDBK-217F2, SF, 35°C
1.5 x 106
Max
200
300
200
10
10
10
10
2200
1000
1000
180
120
500
90
60
125
Unit
s
mVpk
s
%
ms
%
ms
µF
dB
M
g
Hr
Notes: Electrical Performance Characteristics Table
1. Parameter is tested as part of design characterization or after design changes. Thereafter, parameter shall be guaranteed to the
limits specified.
2. Parameter verified during line and load regulation tests.
3. Output load current must be distributed such that at least 20% of the total load current is being provided by one of the outputs.
4. Load current split equally between outputs on dual output models.
5. Cross regulation is measured with 20% rated load on output under test while changing the load on the other output from 20% to
80% of rated.
6. Guaranteed for a D.C. to 20 MHz bandwidth. Tested using a 20 kHz to 10 MHz bandwidth using the circuit shown below.
7. Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in
excess of the maximum limit may interfere with the proper operation of the converter’s overload protection, causing erratic
behavior during turn-on.
8. Overload power dissipation is defined as the device power dissipation with the load set such that VOUT = 90% of nominal.
9. Load step transition time  10 s.
10. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1% of its steady state value
11. Line step transition time 100 s.
12. Turn-on delay time from either a step application of input power or a logic low to a logic high transition on the inhibit pin (pin 4)
to the point where VOUT = 90% of nominal.
13. For operation at temperatures between +85°C and +125°C, de-rate the maximum output power linearly from 100% to 75%.
5