English
Language : 

M3H2803R3S_16 Datasheet, PDF (11/12 Pages) International Rectifier – HYBRID-HIGH RELIABILITY RADIATION HARDENED DC-DC CONVERTER
M3H-SERIES
(+28V Input, Single/Dual Output)
Device Screening
Requirement
MIL-STD-883 Method
No Suffix
EM 
Temperature Range
—
-55°C to +85°C
-55°C to +85°C
Element Evaluation
MIL-PRF-38534
Class H w/SEM
N/A
Non-Destructive Bond Pull
Internal Visual
Temperature Cycle
2023
2017
1010
Yes
Yes
Cond C
N/A

Cond C
Constant Acceleration
PIND
Burn-In
2001, Y1 Axis
2020
1015
3000 Gs
N/A
160 hrs @ 125°C
3000 Gs
N/A
48 hrs @ 125°C
Final Electrical
(Group A)
PDA
Seal, Fine and Gross
Radiographic
External Visual
MIL-PRF-38534
& Specification
MIL-PRF-38534
1014
2012
2009
-55°C, +25°C,
+85°C
2%
A1, C
N/A
Yes
-55°C, +25°C,
+85°C
N/A
Cond A
N/A

Notes:
 Best commercial practice.
 Any Engineering Model (EM) build with the “EM” Suffix shall only be form, fit and functional equivalent to its
Flight Model (FM) counterpart, and it may not meet the radiation performance. The EM Model shall not be expected
comply with MIL-PRF-38534 flight quality/workmanship standards, and configuration control. An EM build may use
electrical equivalent commercial grade components. IR HiRel will provide a list of non-compliance items upon request.
Part Numbering
IR HiRel Headquarters: 101 N. Sepulveda Blvd., El Segundo, California 90245, USA Tel: (310) 252-7105
IR HiRel Leominster: 205 Crawford St., Leominster, Massachusetts 01453, USA Tel: (978) 534-5776
IR HiRel San Jose: 2520 Junction Avenue, San Jose, California 95134, USA Tel: (408) 434-5000
Data and specifications subject to change without notice.
11
2016-05-19