English
Language : 

AUIRS20302S_15 Datasheet, PDF (5/28 Pages) International Rectifier – Pre-regulated Three Phase Gate Driver
AUIRS20302S
Absolute Maximum Ratings
Absolute Maximum Ratings indicate sustained limits beyond which damage to the device may occur. All voltage parameters are absolute
voltages referenced to VSS, all currents are defined positive into any lead. An operation above the absolute maximum limit is not implied and
could damage the part. The thermal resistance and power dissipation ratings are measured under board mounted and free air conditions
Symbol
VB1,2,3
VHO1,2,3
VS1,2,3
VPR
VCP
COM
VLO1,2,3, / FLT
VIN
Can/Cap
EN/Frst
dV/dt
RthJA
TJ
TS
TReflow
Definition
High side floating supply voltage
High side floating output voltage
High side offset voltage
Low side supply voltage
Charge pump output voltage
Power ground
Low side output voltage LO#; FLT pin
Input pin voltage (LIN#, HIN#,)
Over-current comparator inputs
Enable & Fault Reset inputs
High side floating voltage slew rate
Junction to ambient thermal resistance
Maximum operating junction temperature
Maximum storage temperature
Reflow max. temperature (60 sec.)
Min.
-0.3
VS1,2,3 - 0.3
VB 1,2,3 - 20
-0.3
-0.3
-5
-0.3
-0.3
-0.3
-0.3
—
—
-55
—
Max. Units
220
VB 1,2,3 + 0.3
VB 1,2,3 + 0.3
17
17
5
V
VPR + 0.3
VPR + 0.3
VPR + 0.3
VPR + 0.3
50
80
150
V/ns
°C/W
150
°C
260
Recommended Operating Conditions
The Input/Output timing diagram is shown in figure 1. For proper operation the device should be used within the recommended conditions.
All voltage parameters are referenced to VSS. The VS & COM offset rating are tested with all supplies biased at 15V differential.
Symbol
VB1,2,3
VHO 1,2,3
VS 1,2,3
VPR
VLO1,2,3
COM
VHO1,2,3
VLO1,2,3
VIN
Vcan/cap
VCP
Definition
High side floating supply voltage
High side output voltage HO#
High side floating supply voltage
Low side supply voltage
Low side output voltage LO#
Power ground
High side output voltage
Low side output voltage
Logic input voltage LIN, HIN, EN, CAp, CAn, FRST
Common mode voltage on the CAN & CAP inputs
Charge Pump Output Voltage
Min.
VS1,2,3 +6
VS1,2,3-0.3
(Note 1)
6
-0.3
-5
VS1,2,3
COM
VSS-0.3
0
-
Max.
VS1,2,3 +19
VB1,2,3+0.3
200
17
VPR+0.3
5
VB1,2,3
VPR
VPR
5
15
Units
V
Note 1: Logic operational for VS between COM -5V to COM +200V. Logic state held for VS of COM -5 to COM – VBS.
(Please refer to the Design Tip DT97 -3 for more details).
5 www.irf.com © 2014 International Rectifier
Submit Datasheet Feedback
May 28, 2014