AUIPS1042G Datasheet, PDF (4/18 Pages) International Rectifier – SINGLE/DUAL CHANNEL INTELLIGENT POWER LOW SIDE SWITCH | |||
|
◁ |
AUIPS1041(L)(R) / AUIPS1042G
Static Electrical Characteristics
Tj= -40..150°C, Vcc=6..28V (unless otherwise specified), typical value are given for Tj=25°C
Symbol Parameter
Min. Typ. Max. Units
Rds(on)
ON state resistance Tj=25°C
ON state resistance Tj=150°C
ï¾
ï¾
80 100
135 175
mï
Idss1
Idss2
Drain to source leakage current
Drain to source leakage current
ï¾
0.1
2
ï¾
0.2
4
µA
V clamp1 Drain to source clamp voltage 1
36
38
ï¾
V clamp2
Vin clamp
Drain to source clamp voltage 2
IN to source pin clamp voltage
ï¾
39
42
5.5 6.5 7.5
V
Vth
Input threshold voltage
ï¾
1.7
ï¾
Test Conditions
Vin=5V, Ids=3A
Vcc=14V, Tj=25°C
Vcc=28V, Tj=25°C
Id=10mA
Id=1A
Iin=1mA
Id=10mA
Switching Electrical Characteristics
Vcc=14V, Resistive load=5ï, Rinput=0ï, Vin=5V, Tj=25°C
Symbol Parameter
Tdon
Turn-on delay time to 20%
Tr
Rise time 20% to 80%
Tdoff
Turn-off delay time to 80%
Tf
Fall time 80% to 20%
Eon + Eoff Turn on and off energy
Min.
2
2
15
4
ï¾
Typ.
7
7
40
10
0.2
Max.
15
20
150
20
ï¾
Units
µs
mJ
Test Conditions
See figure 2
Protection Characteristics
Tj= -40..150°C, Vcc=6..28V (unless otherwise specified), typical value are given for Tj=25°C
Symbol Parameter
Min. Typ. Max. Units
Tsd
Over temperature threshold
150(2) 165 ï¾
°C
Isd
Over current threshold
2.7 4.5
6
A
OV
Over voltage protection ( not active when 34 37
ï¾
V
the device is ON )
Vreset
IN protection reset threshold
ï¾
1.7
ï¾
V
Treset
Time to reset protection
15(2) 50 200
µs
(2) Guaranteed by design
Test Conditions
See figure 1
See figure 1
Vin=0V, Tj=25°C
Diagnostic
Tj= -40..150°C, Vcc=6..28V (unless otherwise specified), typical value are given for Tj=25°C
Symbol Parameter
Min. Typ. Max. Units
Iin, on
ON state IN positive current
10
32
80
Iin, off
OFF state IN positive current
120 230 350
µA
( after protection latched )
Test Conditions
Vin=5V
Vin=5V
www.irf.com