English
Language : 

AHE28XXS_07 Datasheet, PDF (3/8 Pages) International Rectifier – HYBRID-HIGH RELIABILITY DC/DC CONVERTER
AHE28XXS Series
Specifications
TCASE = -55°C to +105°C, VIN = +28V ± 5% unless otherwise specified
Absolute Maximum Ratings
Input Voltage 5
Power Output
-0.5V to +50VDC
Internally limited, 17.5W typ. for AHE2805S/ES, 22.5W typ. for AHE2812S/ES and AHE2815S/ES
Soldering Temperature 300°C for 10 seconds
Temperature Range 1 Operating Temperature
-55°C to +125°C
Storage Case Temperature -65°C to +135°C
Parameter
Conditions
-55°C ≤ Tc ≤ +105°C
Vin = 28 Vdc ±5%,CL = 0
Unless otherwise specified
AHE2805S/ES
AHE2812S/ES
AHE2815S/ES
Static Characteristic
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
Units
OUTPUT
Voltage
Current
Ripple
Accuracy
Power1
REGULATION
Line
Load
INPUT
Voltage Range4
Current
Ripple Current
Efficiency
Capacitive Load
Load fault power
dissipation4
Isolation
Dynamic
Characteristic
Step Load Changes
Output
Transient
Recovery2
Step Line Changes
VIN=17 to 40 VDC
IOUT=0 to Full Load
Full Load, DC to 1MHz
TCASE = 25°C, IOUT = 0
VIN = 17 to 40 VDC
IOUT = 0 to Full Load
Inhibited
No Load
Full Load
TCASE = +25°C
Half load to Full load
No effect on performance
Input to Output @ 500Vdc
50% Load 100% Load
No Load 50% Load
50% Load No Load
50% Load 100% Load
No Load 50% Load
50% Load No Load
4.90
5.00
5.10
11.76 12.00 12.24 14.70 15.00 15.30 VDC
0.0
3000
0.0
1667
0.0
1333 mADC
20
60
30
60
30
60
mVp-p
4.95
5.00
5.05
11.88 12.00 12.12 14.85 15.00 15.15 VDC
15
20
20
W
±0.5
±1.0
±0.5
±1.0
±0.5
±1.0
±0.5
±1.0
±0.5
±1.0 %
±0.5
±1.0
17
28
40
17
28
40
17
28
40
VDC
8.0
18
8.0
18
8.0
18
mADC
35
35
35
mADC
20
50
25
50
25
50
mV p-p
78
82
500
79
83
200
80
84
%
200
µF
6.0
6.0
6.0 W
100
100
100
MΩ
±150
-300
+300
25
500
7.0
±200
-400
+400
25
500
7.0
±200
-400
+400
25
500
7.0
mVpk
mVpk
mVpk
µs
µs
ms
Output
Transient
Recovery2
TURN –ON
Overshoot
Delay3
Input step 17 to 40VDC
Input step 40 to 17VDC
Input step 17 to 40VDC
Input step 40 to 17VDC
VIN = 17 to 40VDC
IOUT = 0 to Full Load
+180
-600
400
400
0
500
8.0
14
+180
-600
400
400
300
600
8.0
14
+180
-600
400
400
300
8.0
mVpk
mVpk
µs
µs
750 mVpk
14
ms
Load Fault Recovery4
VIN = 17 to 40VDC
8.0
14
8.0
14
8.0
14
ms
Weight
Standard Package
60
60
60
g
Flange Package
65
65
65
Notes to Specifications
1. Above +105°C case temperature, derate output power linearly to 0 at 125°C case.
2. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1.0% of VOUT at 50% load.
See typical waveforms.
3. Turn-on delay time measurement is for either an application of power at the input or a signal at the shutdown pin.
4. For operation at 16VDC, derate output power by 33%.
5. Above +85°C case temperature, derate maximum input voltage linearly to 33V at +125°C case.
www.irf.com
3