English
Language : 

AC100 Datasheet, PDF (4/14 Pages) Intronics Power, Inc. – ISOLATED AC-DC Converter
AC100 SERIES
Rev C December 2007
„ 4. Technical Specifications
(All specifications are typical at nominal input, full load at 25℃ unless otherwise noted.)
PARAMETER
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Continuous
Operating Temperature
NOTES and CONDITIONS
Device
Storage Temperature
Input/Output Isolation Voltage
1 minute
Min. Typical Max. Units
90
0
-20
4242
264 Vdc
+40
℃
+85
℃
Vdc
INPUT CHARACTERISTICS
Operating Voltage Range
Input Frequency Range
Maximum Input Current
Power factor correction
No-Load Input Power
Leakage Current
Inrush Current
100% Load, Vin=90Vac
100% Load, Vin=Nominal Vin
Vin=264Vac
Vin=240Vac, cold start at 250C.
100
240 Vac
47
63
Hz
1.5
A
0.9
AC100S050
7.0
AC100S090
6.0
AC100S120
5.0
AC100S150
5.0
W
AC100S180
5.0
AC100S240
5.0
AC100S480
4.0
3.5 mA
80
A
OUTPUT CHARACTERISTIC
Output Voltage Set Point
Operating Output Current Range
Holdup Time
Output Voltage Regulation
Load Regulation
Line Regulation
Vin=Nominal Vin , Io=Io.max, Tc=25℃
Vin=115Vac
10% load to Full load
Vin=high line to low line
AC100S050 4.95 5.0 5.05
AC100S090 8.91 9.0 9.09
AC100S120 11.88 12.0 12.12
AC100S150 14.85 15.0 15.15 Vdc
AC100S180 17.82 18.0 18.18
AC100S240 23.76 24.0 24.24
AC100S480 47.52 48.0 48.48
AC100S050
20.0
AC100S090
11.2
AC100S120
8.4
AC100S150
6.7
A
AC100S180
5.6
AC100S240
4.2
AC100S480
2.1
20
mS
±1.0
%
±0.5
%
Output Voltage Ripple and Noise
Peak-to-Peak
20MHz bandwidth
Full load, 0.1uF ceramic and 220uF E.L capacitor
Full load, 0.1uF ceramic and 10uF E.L capacitor
AC100S050
AC100S090
AC100S120
AC100S150
AC100S180
AC100S240
AC100S480
100
90
mV
120
150
180
240
mV
480
Page 4