7.3 Test Set-Up
The basic test set-up to measure parameters such as efficiency and
load regulation is shown in Figure 8. When testing the Intronics power’s
AC100 series under any transient conditions please ensure that the
transient response of the source is sufficient to power the equipment
under test. We can calculate the
• Efficiency
• Load regulation and line regulation.
The value of efficiency is defined as:
η = Vo × Io ×100%
Pin
Where: Vo is output voltage,
Io is output current,
Pin is input power,
The value of load regulation is defined as:
Load.reg = VFL −VNL ×100%
VNL
Where: VFL is the output voltage at full load
VNL is the output voltage at 10% load
The value of line regulation is defined as:
Line.reg = VHL −VLL ×100%
VLL
Where: VHL is the output voltage of maximum input voltage at full load.
VLL is the output voltage of minimum input voltage at full load.
AC
Pin
Supply
L
+Vo
N
-Vo
A
V
Load
AC100 SERIES
Rev C December 2007
7.4 Output Ripple and Noise Measurement
The test set-up for noise and ripple measurements is shown in Figure
10. Measured method :
Add a terminal wire is 50mmMIN that the output end needs to connect
the sub length of line of one end .
1. Add a 0.1 uF ceramic capacitor and a 220 uF electrolytic capacitor
to output at 20 MHz Band Width for AC100S050 , AC100S090 and
AC100S120.
2. Add a 0.1 uF ceramic capacitor and a 10 uF electrolytic capacitor to
output at 20 MHz Band Width for AC100S150 , AC100S180 ,
AC100S240 and AC100S480.
Terminal wire
AC
Suppl
L +Vo
N -Vo
AC100
Loa
+
0.1uF
Oscillosco
10uF/100V or220uF/35V
Figure 10. Output Voltage Ripple and Noise Measurement Set-Up
7.5 Output Capacitance
Intronics power’ AC100 series converters provide unconditional stability
with or without external capacitors. Intronics power’ converters are
designed to work with load capacitance up-to 1000uF per amp.
7.6 EMI
„ Conductive EMI meets CISPR/FCC Class B
Figure 8. AC100 Series Test Setup
Page 11