English
Language : 

ISL70001ASEH Datasheet, PDF (9/25 Pages) Intersil Corporation – Rad Hard and SEE Hard 6A Synchronous Buck Regulator
ISL70001ASEH
Electrical Specifications Unless otherwise noted, VIN = AVDD = DVDD = PVINx = EN = M/S = 3V or 5.5V;
GND = AGND = DGND = PGNDx = TDI = TDO = ZAP = 0V; FB = 0.65V; PORSEL = VIN for 4.5V ≤ VIN ≤ 5.5V and GND for VIN < 4.5V,
SYNC = LXx = Open Circuit; PGOOD is pulled up to VIN with a 1k resistor; REF is bypassed to GND with a 220nF capacitor; SS is bypassed to GND with a
100nF capacitor; IOUT = 0A; TA = TJ = +25°C. (Note 11). Boldface limits apply over the operating temperature range, -55°C to +125°C; over a total iodizing
dose of 100krad(Si) with exposure at a high dose rate of 50 - 300krad(Si)/s; and over a total iodizing dose of 50krad(Si) with exposure at a low dose rate
of <10mrad(Si)/s. (Continued)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
(Note 12) (Note 11) (Note 12)
UNITS
SOFT-START
Soft-Start Source Current
SS = GND
20
23
27
µA
Soft-Start Discharge ON-Resistance
2.2
4.7
Ω
Soft-Start Discharge Time
256
Clock Cycles
POWER-GOOD SIGNAL
Rising Threshold
Rising Hysteresis
Falling Threshold
Falling Hysteresis
Power-Good Drive
Power-Good Leakage
PROTECTION FEATURES
VFB as a % of VREF, Test Mode
VFB as a % of VREF, Test Mode
VFB as a % of VREF, Test Mode
VFB as a % of VREF, Test Mode
VIN = 3V, PGOOD = 0.4V, EN = GND
VIN = PGOOD = 5.5V
107
111
115
%
2
3.5
5
%
85
89
93
%
2
3.5
5
%
7.3
8.2
mA
0.001
1
µA
Undervoltage Monitor
Undervoltage Trip Threshold
Undervoltage Recovery Threshold
Overcurrent Monitor
VIN = 3V, VFB as a % of VREF, Test mode
VIN = 3V, VFB as a % of VREF, Test mode
71
75
79
%
84
88
92
%
Overcurrent Trip Level
LX4 Power Block, Test Mode, (Note 15)
1.3
1.9
2.5
A
Overcurrent Trip Counts
LX4 Power Block, Test Mode (Note 14)
2
Overcurrent or Short-Circuit Duty-Cycle
VIN = 3V, SS interval = 200µs, Test Mode, Fault
interval divided by hiccup interval
0.8
5
%
NOTES:
11. Typical values shown are not guaranteed. Guaranteed min/max values are provided in the SMD.
12. Compliance to datasheet limits is assured by one or more methods: production test, characterization and/or design.
13. Limits do not include tolerance of external feedback resistors. The 0A to 6A output current range may be reduced by Minimum LXx On Time and
Minimum LXx Off Time specifications.
14. Limits established by design, characterization or analysis and are not production tested.
15. During an output short-circuit, peak current through the power block(s) can continue to build beyond the overcurrent trip level by up to 3A. With all
six power blocks connected, peak current through the power blocks and output inductor could reach (6 x 2.5A) + 3A = 18A..
9