English
Language : 

X9317_09 Datasheet, PDF (8/15 Pages) Intersil Corporation – Digitally Controlled Potentiometer (XDCP™)
X9317
Power-up and Down Requirements
The recommended power-up sequence is to apply VCC/VSS
first, then the potentiometer voltages. During power-up, the
data sheet parameters for the DCP do not fully apply until
AC Timing
1ms after VCC reaches its final value. The VCC ramp spec is
always in effect. In order to prevent unwanted tap position
changes, or an inadvertent store, bring the CS and INC high
before or concurrently with the VCC pin on power-up.
CS
tCI
INC
tCYC
tIL
tIH
tIC
tID
tDI
tCPHS
90% 90%
10%
tCPHNS
tF
tR
U/D
tIW
RW
(3)
MI
Typical Performance Characteristic
0
-50
-100
-150
-200
-250
-300
-350
-55 -45 -35 -25 -15 -5 5 15 25 35 45 55 65 75 85 95 105115 125
TEMPERATURE (°C)
FIGURE 1. TYPICAL TOTAL RESISTANCE TEMPERATURE COEFFICIENT
8
FN8183.6
December 16, 2009