series with the integrating capacitor. The effect of the
resistor is to introduce a small pedestal voltage on to the
integrator output at the beginning of the reference integrate
phase. By careful selection of the ratio between this resistor
and the integrating resistor (a few tens of ohms in the
recommended circuit), the comparator delay can be
compensated and the maximum clock frequency extended
by approximately a factor of 3. At higher frequencies, ringing
and second order breaks will cause significant non-
linearities in the first few counts of the instrument. See
Application Note AN017.
The minimum clock frequency is established by leakage on
the auto-zero and reference caps. With most devices,
measurement cycles as long as 10s give no measurable
leakage error.
To achieve maximum rejection of 60Hz pickup, the signal
integrate cycle should be a multiple of 60Hz. Oscillator
frequencies of 300kHz, 200kHz, 150kHz, 120kHz, 100kHz,
40kHz, 331/3kHz, etc. should be selected. For 50Hz
rejection, oscillator frequencies of 250kHz, 1662/3kHz,
125kHz, 100kHz, etc. would be suitable. Note that 100kHz
(2.5 readings/sec) will reject both 50Hz and 60Hz.
INTEGRATOR
OUTPUT
AUTO SIGNAL REFERENCE
ZERO INT. INTEGRATE
10,001/ 10,000/
20,001/
COUNTS COUNTS COUNTS MAX.
FULL MEASUREMENT
CYCLE 40,002 COUNTS
BUSY
OVER-RANGE
WHEN APPLICABLE
UNDER-RANGE
WHEN APPLICABLE
DIGIT SCAN
FOR OVER-RANGE
STROBE
DIGIT SCAN
FOR OVER-RANGE
EXPANDED SCALE
BELOW
D5
D4
D3
D2
1000†/
COUNTS
D1
†FIRST D5 OF AZ AND
REF INT ONE COUNT LONGER
AUTO ZERO
SIGNAL INTEGRATE
D5
D4
REFERENCE
INTEGRATE
D3
D2
D1
FIGURE 6. TIMING DIAGRAM FOR OUTPUTS
The clock used should be free from significant phase or
frequency jitter. Several suitable low-cost oscillators are
shown in the Typical Applications section. The multiplexed
output means that if the display takes significant current from
the logic supply, the clock should have good PSRR.
Zero-Crossing Flip-Flop
The flip-flop interrogates the data once every clock pulse
after the transients of the previous clock pulse and half-clock
pulse have died down. False zero-crossings caused by clock
pulses are not recognized. Of course, the flip-flop delays the
true zero-crossing by up to one count in every instance, and
if a correction were not made, the display would always be
one count too high. Therefore, the counter is disabled for
one clock pulse at the beginning of phase 3. This one-count
delay compensates for the delay of the zero-crossing
flip-flop, and allows the correct number to be latched into the
display. Similarly, a one-count delay at the beginning of
phase 1 gives an overload display of 0000 instead of 0001.
No delay occurs during phase 2, so that true ratiometric
readings result.
Evaluating The Error Sources
Errors from the “ideal” cycle are caused by:
1. Capacitor droop due to leakage.
2. Capacitor voltage change due to charge “suck-out” (the
reverse of charge injection) when the switches turn off.
3. Non-linearity of buffer and integrator.
4. High-frequency limitations of buffer, integrator, and
comparator.
5. Integrating capacitor non-linearity (dielectric absorption).
6. Charge lost by CREF in charging CSTRAY.
7. Charge lost by CAZ and ClNT to charge CSTRAY.
Each error is analyzed for its error contribution to the
converter in application notes listed on the back page,
specifically Application Note AN017 and Application Note
AN032.
Noise
The peak-to-peak noise around zero is approximately 15μV
(peak-to-peak value not exceeded 95% of the time). Near
full scale, this value increases to approximately 30μV. Much
of the noise originates in the auto-zero loop, and is
proportional to the ratio of the input signal to the reference.
Analog And Digital Grounds
Extreme care must be taken to avoid ground loops in the
layout of ICL7135 circuits, especially in high-sensitivity
circuits. It is most important that return currents from digital
loads are not fed into the analog ground line.
8