English
Language : 

X9C102_06 Datasheet, PDF (6/11 Pages) Intersil Corporation – Digitally Controlled Potentiometer
X9C102, X9C103, X9C104, X9C503
A.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified)
Symbol
tCl
tlD
tDI
tlL
tlH
tlC
tCPH
tCPH
tIW (5)
tCYC
tR, tF(5)
tPU(5)
tR VCC(5)
Parameter
CS to INC setup
INC HIGH to U/D change
U/D to INC setup
INC LOW period
INC HIGH period
INC inactive to CS inactive
CS deselect time (STORE)
CS deselect time (NO STORE)
INC to VW/RW change
INC cycle time
INC input rise and fall time
Power-up to wiper stable
VCC power-up rate
Min.
100
100
2.9
1
1
1
20
100
2
0.2
Limits
Typ.(6)
100
500
Max.
500
50
Unit
ns
ns
µs
µs
µs
µs
ms
ns
µs
µs
µs
µs
V/ms
POWER-UP AND DOWN REQUIREMENTS
At all times, voltages on the potentiometer pins must be less than ±VCC. The recall of the wiper position from nonvola-
tile memory is not in effect until the VCC supply reaches its final value. The VCC ramp rate spec is always in effect.
A.C. TIMING
CS
tCI
INC
tCYC
tIL
tIH
tIC
tID
tDI
tCPH
90% 90%
10%
tF
tR
U/D
tIW
VW
MI (8)
Notes: (6) Typical values are for TA = 25°C and nominal supply voltage.
(7) This parameter is periodically sampled and not 100% tested.
(8) MI in the A.C. timing diagram refers to the minimum incremental change in the VW output due to a change in the wiper position.
6
FN8222.1
December 20, 2006