Symbol
Parameter
ICC VCC active current
Limits
Min. Typ.(4) Max.
1
3
ISB Standby supply current
200
750
ILI
CS, INC, U/D input leakage
±10
current
VIH CS, INC, U/D input HIGH
2
voltage
VIL CS, INC, U/D input LOW
0.8
voltage
CIN(5) CS, INC, U/D input
10
capacitance
Unit
mA
µA
µA
Test Conditions
CS = VIL, U/D = VIL or VIH and
INC = 0.4V to 2.4V @ max. tCYC
CS = VCC - 0.3V, U/D and INC = VSS
or VCC - 0.3V
VIN = VSS to VCC
V
V
pF VCC = 5V, VIN = VSS, TA = 25°C, f = 1MHz
ENDURANCE AND DATA RETENTION
Parameter
Minimum endurance
Data retention
Min.
100,000
100
Unit
Data changes per bit per register
years
Test Circuit #1
Test Circuit #2
VR/RH
VH/RH
Test Point
VS
Test Point
VW/RW
VW/RW
Force
VL/RL
VL/RL
Current
Test Circuit #3
Macro Model
RTOTAL
RL
RH
CL
CH
10pF CW
10pF
25pF
RW
A.C. CONDITIONS OF TEST
Input pulse levels
Input rise and fall times
Input reference levels
0V to 3V
10ns
1.5V
5
FN8222.1