English
Language : 

X9312 Datasheet, PDF (6/9 Pages) Xicor Inc. – E2POT™ Nonvolatile Digital Potentiometer
X9312
A.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified)
Symbol
tCl
tlD
tDI
tlL
tlH
tlC
tCPH
tCPH
tIW
tCYC
tR, tF7
tPU7
tR VCC7
Parameter
CS to INC setup
INC HIGH to U/D change
U/D to INC setup
INC LOW period
INC HIGH period
INC inactive to CS inactive
CS deselect time (STORE)
CS deselect time (NO STORE)
INC to Vw change
INC cycle time
INC input rise and fall time
Power-up to wiper stable
VCC power-up rate
Min.
100
100
1
1
1
1
20
100
4
0.2
Limits
Typ.6
Max.
100
500
500
500
50
Unit
ns
ns
µs
µs
µs
µs
ms
ns
µs
µs
µs
µs
V/ms
POWER-UP AND DOWN REQUIREMENTS
There are no restrictions on the sequencing of VCC and the voltages applied to the potentiometer pins during power-
up or power-down conditions. During power-up, the data sheet parameters for the DCP do not fully apply until 1
millisecond after VCC reaches is final value. The VCC ramp spec is always in effect.
A.C. TIMING
CS
tCI
INC
tCYC
tIL
tIH
tIC
tID
tDI
tCPH
90% 90%
10%
tF
tR
U/D
tIW
VW
MI (8)
Notes: (6) Typical values are for TA = 25°C and nominal supply voltage.
(7) This parameter is sample tested.
(8) MI in the A.C. timing diagram refers to the minimum incremental change in the VW output due to a change in the wiper position.
6
FN8176.0
March 15, 2005