English
Language : 

X9312 Datasheet, PDF (5/9 Pages) Xicor Inc. – E2POT™ Nonvolatile Digital Potentiometer
X9312
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.)
Symbol
ICC
ISB
ILI
VIH
VIL
CIN(5)
Parameter
VCC active current (Increment)
Standby supply current
CS, INC, U/D input leakage current
CS, INC, U/D input HIGH voltage
CS, INC, U/D input LOW voltage
CS, INC, U/D input capacitance
Min.
Limits
Typ.(4)
1
Max.
3
500
1000
±10
2
VCC + 1
-1
0.8
10
Unit
mA
µA
µA
V
V
pF
Test Conditions
CS = VIL, U/D = VIL or VIH and
INC = 0.4V/2.4V @ max. tCYC
CS = VCC - 0.3V, U/D and
INC = VSS or VCC - 0.3V
VIN = VSS to VCC
VCC = 5V, VIN = VSS, TA = 25°C,
f = 1MHz
ENDURANCE AND DATA RETENTION
Parameter
Minimum endurance
Data retention
Min.
100,000
100
Unit
Data changes per bit
Years
Notes: (4) Typical values are for TA = 25°C and nominal supply voltage.
(5) This parameter is periodically sampled and not 100% tested.
Test Circuit #1
Test Circuit #2
Circuit #3 SPICE Macro Model
VH/RH
VS
Test Point
VW/RW
VL/RL
VH/RH
Test Point
VWW/RW
Force
VLL/RL
Current
RTOTAL
RH
RL
CH
CW
CL
10pF
10pF
25pF
RW
A.C. CONDITIONS OF TEST
Input pulse levels
Input rise and fall times
Input reference levels
0V to 3V
10ns
1.5V
5
FN8176.0