English
Language : 

ISL22349_09 Datasheet, PDF (6/13 Pages) Intersil Corporation – Quad Digitally Controlled Potentiometers
ISL22349
Operating Specifications Over the recommended operating conditions unless otherwise specified. (Continued)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
(Note 13) (Note 3) (Note 13) UNIT
tSU:A A2, A1 and A0 Setup Time
Before START condition
600
ns
tHD:A A2, A1 and A0 Hold Time
After STOP condition
600
ns
NOTES:
3. Typical values are for TA = +25°C and 3.3V supply voltage.
4. LSB: [V(RW)127 – V(RW)0]/127. V(RW)127 and V(RW)0 are V(RW) for the DCP register set to 7F hex and 00 hex respectively. LSB is the
incremental voltage when changing from one tap to an adjacent tap.
5. ZS error = V(RW)0/LSB.
6. FS error = [V(RW)127 – VCC]/LSB.
7. DNL = [V(RW)i – V(RW)i-1]/LSB-1, for i = 1 to 127. i is the DCP register setting.
8. INL = [V(RW)i – i • LSB – V(RW)0]/LSB for i = 1 to 127.
9. VMATCH = [V(RWx)i – V(RWy)i]/LSB, for i = 1 to 127, x = 0 to 3 and y = 0 to 3.
10.
TCV
=
-------M-----a----x----(--V----(---R-----W------)--i--)---–-----M-----i--n----(--V-----(--R-----W------)--i--)------ × ----1----0---6----- for i = 16 to 112 decimal, T = -40°C to +125°C. Max( ) is the maximum value of the wiper
[Max(V(RW)i) + Min(V(RW)i)] ⁄ 2 165°C minimum value of the resistance over the temperature range.
11. This parameter is not 100% tested.
12. tWC is the time from a valid STOP condition at the end of a Write sequence of I2C serial interface, to the end of the self-timed internal non-volatile
write cycle.
13. Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by characterization
and are not production tested.
SDA vs SCL Timing
tF
tHIGH
tLOW
tR
tsp
SCL
tSU:STA
SDA
(INPUT TIMING)
SDA
(OUTPUT TIMING)
tSU:DAT
tHD:STA
tHD:DAT
tAA tDH
tSU:STO
tBUF
A0, A1, and A2 Pin Timing
SCL
START
CLK 1
STOP
SDA
A0, A1, OR A2
tSU:A
tHD:A
6
FN6331.3
May 28, 2009