English
Language : 

HCTS190MS Datasheet, PDF (6/10 Pages) Intersil Corporation – Radiation Hardened Synchronous 4-Bit Up/Down Counter
Specifications HCTS190MS
TABLE 4. DC POST RADIATION ELECTRICAL PERFORMANCE CHARACTERISTICS (Continued)
PARAMETER
Output Voltage Low
Output Voltage High
Input Leakage Current
Noise Immunity
Functional Test
PL to Qn
Pn to Qn
CP to Qn
Cp to RC
CP to TC
U/D to RC
U/D to TC
CE to RC
SYMBOL
(NOTES 1, 2)
CONDITIONS
VOL
VCC = 4.5V and 5.5V, VIH = VCC/2,
VIL = 0.8V, IOL = 50µA
VOH
VCC = 4.5V and 5.5V, VIH = VCC/2,
VIL = 0.8V , IOH = -50µA
IIN
VCC = 5.5V, VIN = VCC or GND
FN
VCC = 4.5V, VIH = 2.25V, VIL = 0.8V,
(Note 3)
TPLH VCC = 4.5V
TPHL VCC = 4.5V
TPLH VCC = 4.5V
TPHL VCC = 4.5V
TPLH VCC = 4.5V
TPHL VCC = 4.5V
TPLH VCC = 4.5V
TPHL VCC = 4.5V
TPLH VCC = 4.5V
TPHL VCC = 4.5V
TPLH VCC = 4.5V
TPHL VCC = 4.5V
TPLH VCC = 4.5V
TPHL VCC = 4.5V
TPLH VCC = 4.5V
TPHL VCC = 4.5V
TEMPERATURE
+25oC
200K RAD
LIMITS
MIN MAX UNITS
-
0.1
V
+25oC
+25oC
+25oC
VCC
-
V
-0.1
-
±5
µA
-
-
-
+25oC
+25oC
+25oC
+25oC
+25oC
+25oC
+25oC
+25oC
+25oC
+25oC
+25oC
+25oC
+25oC
+25oC
+25oC
+25oC
2
37
ns
2
44
ns
2
24
ns
2
41
ns
2
29
ns
2
27
ns
2
19
ns
2
29
ns
2
39
ns
2
39
ns
2
36
ns
2
38
ns
2
33
ns
2
38
ns
2
21
ns
2
31
ns
NOTES:
1. All voltages referenced to device GND.
2. AC measurements assume RL = 500Ω, CL = 50pF, Input TR = TF = 3ns, VIL = GND, VIH = 3V.
3. For functional tests VO ≥ 4.0V is recognized as a logic “1”, and VO ≤ 0.5V is recognized as a logic “0”.
TABLE 5. BURN-IN AND OPERATING LIFE TEST, DELTA PARAMETERS (+25oC)
PARAMETER
GROUP B
SUBGROUP
DELTA LIMIT
ICC
5
12µA
IOL/IOH
5
-15% of 0 Hour
Spec Number 518614
6