English
Language : 

X93254 Datasheet, PDF (5/10 Pages) Intersil Corporation – Dual Digitally Controlled Potentiometers
X93254
A.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified. In the
table, CS, INC, U/D, RH and RL are used to refer to either CS1 or CS2, etc.)
Symbol
Parameter
Limits
Min.
Typ.(6)
Max.
Unit
tCl
tlD
tDI
tlL
tlH
tlC
tCPH
tCPH
tCYC
tR, tF(6)
tR VCC(6)
tWR
CS to INC setup
INC HIGH to U/D change
U/D to INC setup
INC LOW period
INC HIGH period
INC Inactive to CS inactive
CS Deselect time (NO STORE)
CS Deselect time (STORE)
INC cycle time
INC input rise and fall time
VCC power-up rate
Store cycle
100
ns
100
ns
100
ns
1
µs
1
µs
1
µs
250
ns
10
ms
2
µs
500
µs
1
10,000
V/ms
5
10
ms
POWER-UP AND DOWN REQUIREMENTS
There are no restrictions on the power-up or power-down conditions of VCC and the voltages applied to the potenti-
ometer pins provided that VCC is always more positive than or equal to VH and VL, i.e., VCC ≥ VH,VL. The VCC ramp
rate spec is always in effect.
A.C. TIMING (In the diagram, CS, INC, U/D, RH and RL are used to refer to either CS1 or CS2, etc.)
CS
tCI
INC
U/D
tCYC
tIL
tIH
tIC
tID
tDI
(Store)
tCPH
90% 90%
10%
tF
tR
5
FN8186.0
March 1, 2005