X93254
ABSOLUTE MAXIMUM RATINGS
Temperature under bias .................... -65°C to +135°C
Storage temperature ......................... -65°C to +150°C
Voltage on CS, INC, U/D, RH, RL and VCC
with respect to VSS .............................. -1V to +6.5V
Lead temperature (soldering 10 seconds) ......... 300°C
Maximum reflow temperature (40 seconds) ...... 240°C
Maximum resistor current ..................................... 2mA
RECOMMENDED OPERATING CONDITIONS
Temperature
Industrial
Min.
-40°C
Max.
+85°C
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; the functional operation of
the device (at these or any other conditions above
those listed in the operational sections of this specifi-
cation) is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect
device reliability.
Supply Voltage (VCC)
X93254
Limits
3V ± 10%(7)
POTENTIOMETER CHARACTERISTICS (Over recommended operating conditions unless otherwise stated.)
Symbol
RTOT
VR
RW
IW
CH/CL/CW
Parameter
End to end resistance
RH, RL terminal voltages
Power rating
Noise
Wiper Resistance
Wiper Current
Resolution
Absolute linearity(1)
Relative linearity(2)
RTOTAL temperature coefficient
Potentiometer capacitances
Min.
37.5
0
Limits
Typ. Max. Unit
Test Conditions/Notes
50
62.5 kΩ (5)
-120
VCC
1
V
mW(6)
dBV(6)
(5)
RTOTAL = 50kΩ(5)
Ref: 1kHz(5)
1000 Ω (5) (6)
0.6 mA (5) (6)
3
% (5)
±1
MI(3) VH(n)(actual) - VH(n)(expected)(5)
±0.5 MI(3) VH(n+1) - [VH(n)+MI(5)
±35
ppm/°C (5) (6)
10/10/25
pF See circuit #2(5)
Notes: (1) Absolute linearity is utilized to determine actual wiper voltage versus expected voltage = (VH(n)(actual) - VH(n)(expected)) = ±1 Ml
Maximum. n = 1 .. 29 only
(2) Relative linearity is a measure of the error in step size between taps = VH(n+1) - [VH(n) + Ml] = ±0.5 Ml, n = 1 .. 29 only.
(3) 1 Ml = Minimum Increment = RTOT/31.
(4) Typical values are for TA = 25°C and nominal supply voltage.
(5) This parameter only applies to a single potentiometer.
(6) This parameter is guaranteed by characterization.
(7) When performing multiple write operations, VCC must not decrease by more than 150mV from its initial value.
3
FN8186.0
March 1, 2005