D.C. Operating Specifications Over recommended operating conditions unless otherwise specified
SYMBOL
ICC1
PARAMETER
VCC active current (increment)
ICC2
ISB
VCC active current (Store) (EEPROM
Store)
Standby supply current
ILI
VIH
VIL
CIN (Note 5)
CS, INC, U/D input leakage current
CS, INC, U/D input HIGH voltage
CS, INC, U/D input LOW voltage
CS, INC, U/D input capacitance
TEST CONDITIONS
CS = VIL, U/D = VIL or VIH and
INC = 0.4V @ max. tCYC
CS = VIH, U/D = VIL or VIH and
INC = VIH @ max. tWR
CS = VCC – 0.3V, U/D and
INC = VSS or VCC – 0.3V
VIN = VSS to VCC
VCC = 5V, VIN = VSS, TA = 25°C,
f = 1MHz
MIN.
VCC x 0.7
-0.5
TYP.
(Note 4)
MAX.
50
400
1
±10
VCC + 0.5
VCC x 0.1
10
UNITS
µA
µA
µA
µA
V
V
pF
TEST CIRCUIT #1
TEST CIRCUIT #2
VH/RH
VS
Test Point
VW/RW
VL/RL
VH/RH
Test Point
VWW/RW
Force
VVLL/RL
Current
A.C. Conditions of Test
Input pulse levels
Input rise and fall times
Input reference levels
0V to 3V
10ns
1.5V
CIRCUIT #3 SPICE MACRO MODEL
RTOTAL
RH
RL
CH
CW
CL
10pF
10pF
25pF
RW
5
FN8157.1
September 15, 2005