English
Language : 

X9015 Datasheet, PDF (4/11 Pages) Xicor Inc. – Digitally-Controlled Potentiometer
X9015
Absolute Maximum Ratings
Temperature under bias . . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Voltage on CS, INC, U/D, VH, VL and
VCC with respect to VSS . . . . . . . . . . . . . . . . . . . . . . . . -1V to +7V
∆V = |VH–VL| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5V
Lead temperature (soldering 10s) . . . . . . . . . . . . . . . . . . . . . . 300°C
IW (10s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .±7.5mA
Operating Conditions
Temperature Range
Commercial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to +70°C
Industrial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
Supply Voltage (VCC)
X9015. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V±10%
X9015-2.7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
)
Potentiometer Specifications Over recommended operating conditions unless otherwise stated
SYMBOL
PARAMETER
TEST CONDITIONS/NOTES
RTOTAL
VVH
VVL
RW
RW
IW
End to End Resistance Variation
VH/RH Terminal Voltage
VL/RL Terminal Voltage
Power Rating
Wiper Resistance
Wiper Resistance
Wiper Current
Noise
RTOTAL ≤1kΩ
IW = 1mA, VCC = 5V
IW = 1mA, VCC = 2.7V
Ref: 1kHz
Resolution
Absolute Linearity (Note 1)
Relative Linearity (Note 2)
RTOTAL Temperature Coefficient
Ratiometric Temperature Coefficient
Vw(n)(actual)–Vw(n)(expected)
Vw(n+1)–[Vw(n)+MI]
CH/CL/CW Potentiometer Capacitances
See circuit #3
MIN.
–20
0
0
-3.75
-1
-0.2
TYP.
200
400
-120
3
±300
10/10/25
MAX.
UNIT
+20
%
VCC
V
VCC
V
10
mW
400
Ω
1000
Ω
3.75
mA
dBV
%
+1 MI (Note 3)
+0.2 MI (Note 3)
ppm/°C
±20 ppm/°C
pF
Power Up and Down Requirements
The are no restrictions on the power-up or power-down conditions of VCC and the voltages applied to the potentiometer pins
provided that VCC is always more positive than or equal to VH, VL, and VW, i.e., VCC ≥ VH, VL, VW. The VCC ramp rate spec is
always in effect.
NOTES:
1. Absolute Linearity is utilized to determine actual wiper voltage versus expected voltage = (Vw(n)(actual)–Vw(n)(expected)) = ±1 Ml Maximum.
2. Relative Linearity is a measure of the error in step size between
taps = VW(n+1) – [Vw(n) + Ml] = ±0.2 Ml.
3. 1 Ml = Minimum Increment = RTOT/31.
4. Typical values are for TA = 25°C and nominal supply voltage.
5. This parameter is periodically sampled and not 100% tested.
4
FN8157.1
September 15, 2005