Absolute Maximum Ratings
Supply Voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . 8.0V to 18.0V
Logic Input Voltage Range
(SDA, SCL, ENT, DSQIN 1 and 2, SEL18V 1 and 2) . -0.5V to 7V
Thermal Information
Thermal Resistance (Typical, Notes 2, 3) θJA (°C/W) θJC (°C/W)
QFN Package (Notes 2, 3) . . . . . . . . . .
38
4.5
EPTSSOP Package (Notes 2, 3) . . . . .
35
2.5
Maximum Junction Temperature (Note 4) . . . . . . . . . . . . . . . +150°C
Maximum Storage Temperature Range . . . . . . . . . . -40°C to +150°C
Operating Temperature Range . . . . . . . . . . . . . . . . . -20°C to +85°C
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
NOTES:
2. θJA is measured in free air with the component mounted on a high effective thermal conductivity test board with “direct attach” features. See
Tech Brief TB379.
3. For θJC, the "case temp" location is the center of the exposed metal pad on the package underside.
4. +150°C max junction temperature is intended for short periods of time to prevent shortening the lifetime. Operation close to +150°C junction may
trigger the shutdown of the device even before +150°C, since this number is specified as typical.
Electrical Specifications
VCC = 12V, TA = -20°C to +85°C, unless otherwise noted. Typical values are at TA = +25°C. EN = H, VTOP
VBOT = L, ENT = L, DCL = L, IOUT = 12mA, unless otherwise noted. See software description section for I2C
access to the system.
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
TYP
MAX
UNITS
Operating Supply Voltage Range
8
12
14
V
Standby Supply Current
EN = L
-
1.5
3.0
mA
Supply Current
UNDERVOLTAGE LOCKOUT
IIN
EN = VTOP = VBOT = ENT = H, No Load
-
4.0
8.0
mA
Start Threshold
7.5
-
7.95
V
Stop Threshold
7.0
-
7.55
V
Start to Stop Hysteresis
350
400
500
mV
SOFT-START
COMP Rise Time (Note 5)
(Note 5)
-
8196
-
Cycles
Output Voltage (Note 5)
Line Regulation
Load Regulation
Dynamic Output Current Limiting
VO1
(Refer to Table 1)
13.04 13.3 13.56
V
VO1
(Refer to Table 1)
14.02 14.3 14.58
V
VO1
(Refer to Table 1)
17.94 18.3 18.66
V
VO1
(Refer to Table 1)
19.00 19.3 19.68
V
DVO1,
DVO2
VIN = 8V to 14V; VO = 13.3V
VIN = 8V to 14V; VO = 18.3V
-
4.0
40.0
mV
-
4.0
60.0
mV
DVO1,
DVO2
IO = 0mA to 350mA
IO = 0mA to 750mA
-
50
80
mV
-
100
200
mV
IMAX DCL = 0, ISEL H = 0, ISEL L = 0 (Note 8)
275
305
345
mA
DCL = 0, ISEL H = 0, ISEL L = 1 (Note 8)
515
570
630
mA
DCL = 0, ISEL H = 1, ISEL L = 0 (Note 8)
635
705
775
mA
DCL = 0, ISEL H = 1, ISEL L = 1 (Note 8)
800
890
980
mA
Dynamic Overload Protection Off Time TOFF DCL = 0, Output Shorted (Note 8)
-
900
-
ms
Dynamic Overload Protection On Time
TON
-
51
-
ms
Static Output Current Limiting
Cable Fault CABF Threshold
IMAX
ICAB
DCL = 1 (Note 8)
EN = 1, VO = 19V, No Tone.
-
1000
-
mA
2
10
20
mA
5
FN6412.1