English
Language : 

ISL32610E Datasheet, PDF (5/12 Pages) Intersil Corporation – 16.5kV ESD Protected, 1.8V, Micro Power, 125°C, 1/8 Unit Load, RS-485/RS-422 Differential Receivers
ISL32610E, ISL32611E, ISL32612E
Electrical Specifications Test Conditions: VCC = 1.8V; Unless Otherwise Specified. Typicals are at VCC = 1.8V, TA = +25°C. Boldface
limits apply over the operating temperature range, -40°C to +125°C. (Note 9) (Continued)
PARAMETER
SYMBOL
TEST CONDITIONS
TEMP MIN
MAX
(°C) (Note 8) TYP (Note 8) UNITS
SWITCHING CHARACTERISTICS
Maximum Data Rate
Receiver Input to Output Delay
fMAX
VID = ±1V, VCM = 0V,
(Figure 3)
tPLH, tPHL (Figure 3)
Receiver Skew | tPLH - tPHL |
tSKD (Figure 3)
Receiver Enable to Output High
Receiver Enable to Output Low
Receiver Disable from Output High
Receiver Disable from Output Low
ESD PERFORMANCE
tZH
CL = 15pF, SW = GND,
(Figure 4, Note 12)
tZL
CL = 15pF, SW = VCC,
(Figure 4, Note 12)
tHZ
CL = 15pF, SW = GND,
(Figure 4, Note 12)
tLZ
CL = 15pF, SW = VCC,
(Figure 4, Note 12)
VCC = 1.8V
3V ≤ VCC ≤ 3.6V
VCC = 1.8V
VCC = 3.3V
VCC = 1.8V
VCC = 3.3V
VCC = 1.8V
VCC = 3.3V
VCC = 1.8V
VCC = 3.3V
VCC = 1.8V
VCC = 3.3V
VCC = 1.8V
VCC = 3.3V
Full 256
-
-
kbps
Full 500
-
-
kbps
Full
-
210 1000 ns
25
-
200
-
ns
Full
-
3
125 ns
25
-
6
-
ns
Full
-
1100 4000 ns
25
-
1500
-
ns
Full
-
1100 4000 ns
25
-
1500
-
ns
Full
-
15
75
ns
25
-
6
-
ns
Full
-
15
75
ns
25
-
6
-
ns
RS-485 Pins (A, B)
IEC61000-4-2, Air-Gap Discharge Method
25
-
±16.5
-
kV
IEC61000-4-2, Contact Discharge Method
25
-
±9
-
kV
Human Body Model, From Bus Pins to GND
25
-
±16.5
-
kV
All Pins
Human Body Model (Tested per JESD22-A114E)
25
-
±8
-
kV
Machine Model (Tested per JESD22-A115-A)
25
-
±400
-
V
NOTES:
8. Compliance to data sheet limits is assured by one or more methods: production test, characterization and/or design.
9. Currents into device pins are positive; currents out of device pins are negative. Voltages are referenced to ground unless otherwise specified.
10. The ISL32611E enters SHDN whenever RE switches high, and the ISL32612E enters SHDN whenever RE switches low.
11. Devices meeting these limits are denoted as “1/8 unit load (1/8 UL)” transceivers. The RS-485 standard allows up to 32 Unit Loads on the bus, so
there can be 256 1/8 UL devices on a bus.
12. Not applicable to the ISL32610E.
Test Circuits and Waveforms
GND / VCC RE / RE
B
RO
A
R
SIGNAL
GENERATORS
15pF
B
0V
A
+0.5V
0V
-0.5V
tPLH
tPHL
VOH
RO
50%
50%
VOL
FIGURE 3A. TEST CIRCUIT
FIGURE 3B. MEASUREMENT POINTS
FIGURE 3. RECEIVER PROPAGATION DELAY AND DATA RATE
5
FN7869.0
October 21, 2011