English
Language : 

ISL24212 Datasheet, PDF (5/12 Pages) Intersil Corporation – Programmable VCOM Calibrator with EEPROM and Output Buffer
ISL24212
Electrical Specifications Test Conditions: VDD = 3.3V, AVDD = 18V, RSET = 5kΩ, R1 = 10kΩ, R2 = 10kΩ, (See Figure 5), VCOM_OUT pin
connected to INN, unless otherwise specified. Typicals are at TA = +25°C. Boldface limits apply over the operating temperature range,
-40°C to +85°C. (Continued)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
(Note 6)
MAX
TYP (Note 6) UNITS
VOH Output Swing High
ISC
Short Circuit Current (Sinking)
Short Circuit Current (Sourcing)
SR Slew Rate (Rising)
Slew Rate (Falling)
IL = 5mA
1KΩ || 8pF Load
1KΩ || 8pF Load
17.85
17.9
300
430
450
555
70
116
50
93
V
mA
mA
V/µs
V/µs
tS
Settling Time to 0.2%
BW -3dB Bandwidth
150
ns
60
MHz
EEPROM CHARACTERISTICS
tPROG EEPROM Programming Time (internal)
UP/DOWN COUNTER CONTROL INPUTS (SEE FIGURE 11)
100
ms
VIH
CE and CTL Input Logic High Threshold
0.7*VDD
V
VIL
CE and CTL Input Logic Low Threshold
0.3*VDD
V
ICS_PD CE Input Pull Down Current Sink
0.5
1.5
µA
ICTL CTL Input Bias Current
CTL = GND (sourcing)
7
15
µA
CTL = VDD (sinking)
7
15
µA
tST
CE to CTL Start Delay
50
µs
tREAD EEPROM Recall Time (after CE de-asserted)
10
ms
tH_REJ CTL High Pulse Rejection Width
20
µs
tL_REJ CTL Low Pulse Rejection Width
20
µs
tH_MIN CTL High Minimum Valid Pulse Width
200
µs
tL_MIN CTL Low Minimum Valid Pulse Width
200
µs
tMTC CTL Minimum Time Between Counts
10
µs
VPROG CTL EEPROM Program Voltage (see Figure 9)
4.9
19
V
tPROG CTL EEPROM Programming Signal Time
200
µs
tH_PROP CTL High-to-Mid to DVR_OUT propagation time
65
µs
tL_PROP CTL Low-to-Mid to DVR_OUT propagation time
65
µs
NOTE:
6. Compliance to datasheet limits is assured by one or more methods: production test, characterization and/or design.
5
FN7590.0
March 15, 2011