Electrical Specifications Test Conditions: VDD = 3.3V, AVDD = 18V, RSET = 5kΩ, R1 = 10kΩ, R2 = 10kΩ, (See Figure 5). Typicals are at
TA = +25°C. Boldface limits apply over the operating temperature range, -40°C to +85°C. (Continued)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
(Note 6)
MAX
TYP (Note 6) UNITS
tH_REJ CTL High Pulse Rejection Width
20
µs
tL_REJ CTL Low Pulse Rejection Width
20
µs
tH_MIN CTL High Minimum Valid Pulse Width
200
µs
tL_MIN CTL Low Minimum Valid Pulse Width
200
µs
tMTC CTL Minimum Time Between Counts
10
µs
VPROG CTL EEPROM Program Voltage (see Figure 9)
4.9
19
V
tPROG CTL EEPROM Programming Signal Time
200
µs
tH_PROP CTL High-to-Mid to OUT Propagation Time
65
µs
tL_PROP CTL Low-to-Mid to OUT Propagation Time
65
µs
NOTE:
6. Compliance to datasheet limits is assured by one or more methods: production test, characterization and/or design.
5
FN7587.0
March 15, 2011