English
Language : 

HCS138MS Datasheet, PDF (5/9 Pages) Intersil Corporation – Radiation Hardened Inverting 3-to-8 Line Decoder/Demultiplexer
Specifications HCS138MS
TABLE 4. DC POST RADIATION ELECTRICAL PERFORMANCE CHARACTERISTICS (Continued)
PARAMETER
Output Voltage Low
Output Voltage High
Input Leakage Current
Noise Immunity
Functional Test
Address to Output
Enable to Output
SYMBOL
(NOTES 1, 2)
CONDITIONS
VOL
VCC = 4.5V and 5.5V, VIH = 0.70(VCC),
VIL = 0.30(VCC), IOL = 50µA
VOH
VCC = 4.5V and 5.5V, VIH = 0.70(VCC),
VIL = 0.30(VCC), IOH = -50µA
IIN
VCC = 5.5V, VIN = VCC or GND
FN
VCC = 4.5V, VIH = 0.70(VCC),
VIL = 0.30(VCC), (Note 3)
TPLH VCC = 4.5V
TPHL VCC = 4.5V
TPLH VCC = 4.5V
TPHL VCC = 4.5V
TEMPERATURE
+25oC
200K RAD
LIMITS
MIN MAX UNITS
-
0.1
V
+25oC
+25oC
+25oC
VCC
-
V
-0.1
-
±5
µA
-
-
-
+25oC
+25oC
+25oC
+25oC
2
34
ns
2
34
ns
2
33
ns
2
33
ns
NOTES:
1. All voltages referenced to device GND.
2. AC measurements assume RL = 500Ω, CL = 50pF, Input TR = TF = 3ns, VIL = GND, VIH = VCC.
3. For functional tests VO ≥ 4.0V is recognized as a logic “1”, and VO ≤ 0.5V is recognized as a logic “0”.
TABLE 5. BURN-IN AND OPERATING LIFE TEST, DELTA PARAMETERS (+25oC)
PARAMETER
GROUP B
SUBGROUP
DELTA LIMIT
ICC
5
12µA
IOL/IOH
5
-15% of 0 Hour
TABLE 6. APPLICABLE SUBGROUPS
CONFORMANCE GROUPS
METHOD
GROUP A SUBGROUPS
Initial Test (Preburn-In)
100%/5004
1, 7, 9
Interim Test I (Postburn-In)
100%/5004
1, 7, 9
Interim Test II (Postburn-In)
100%/5004
1, 7, 9
PDA
100%/5004
1, 7, 9, Deltas
Interim Test III (Postburn-In)
100%/5004
1, 7, 9
PDA
100%/5004
1, 7, 9, Deltas
Final Test
100%/5004
2, 3, 8A, 8B, 10, 11
Group A (Note 1)
Sample/5005
1, 2, 3, 7, 8A, 8B, 9, 10, 11
Group B
Subgroup B-5
Sample/5005 1, 2, 3, 7, 8A, 8B, 9, 10, 11, Deltas
Subgroup B-6
Sample/5005
1, 7, 9
Group D
Sample/5005
1, 7, 9
NOTE:
1. Alternate group A inspection in accordance with method 5005 of MIL-STD-883 may be exercised.
READ AND RECORD
ICC, IOL/H
ICC, IOL/H
ICC, IOL/H
ICC, IOL/H
Subgroups 1, 2, 3, 9, 10, 11
Spec Number 518751